Specifications — ipl t pc1, ipl t pc1i
Specifications — IPL T PC1, IPL T PC1i
AC control interface
Connectors
IPL T PC1 .......................... 1 female USA/Edison power connector
IPL T PC1i ......................... 1 female IEC power connector
Voltage
IPL T PC1 .......................... 120 VAC, 50-60 Hz
IPL T PC1i ......................... 220 VAC, 50-60 Hz
Maximum AC load
IPL T PC1 .......................... 12 A, 1440 watts at 120 VAC
IPL T PC1i ......................... 10 A, 2200 watts at 220 VAC
Serial control interface
Serial control port ........................ (1) RS-232 only, 3.5 mm captive screw connectors, 4 pole
Baud rate and protocol ............... 115200 to 300 baud (9600 baud = default) ; 8 (default) or 7 data bits; 1 (default) or 2
stop bits; no parity (default), or even or odd parity
Serial control pin configurations 1 = TX, 2 = RX, 3 = GND, 4 = +5 VDC
Ethernet control interface
Connector ...................................... 1 RJ-45 female connector
Data rate ........................................ 10/100Base-T, half/full duplex with autodetect
Protocols ....................................... ARP, DHCP, ICMP (ping), TCP/IP, UDP/IP, Telnet, HTTP, SMTP
Default settings ............................ Link speed and duplex level = autodetected
IP address = 192.168.254.254
Subnet mask = 255.255.0.0
Gateway = 0.0.0.0
DHCP = off
Web server .................................... Up to 200 simultaneous sessions
7.25 MB nonvolatile user memory
Program control ........................... Extron’s Simple Instruction Set (SIS
™
)
Global Viewer requirements ...... Microsoft
®
Internet Explorer ver. 6 or higher
Contact closure interface (input only)
Quantity/type .............................. 1 contact closure input
Contact input control connector . (1) 3.5 mm captive screw connector, 4 pole (shared with IR output port)
Contact closure (input only)
Input voltage range ......... 0 to 5 VDC, clamped at +5.1 V
Input impedance .............. 10k ohms
Threshold .......................... 1.6 VDC
Pin configuration ......................... 1 = contact input, 2 = GND
IR control interface
IR control port .............................. (1) 3.5 mm captive screw connector, 4 pole (shared with contact closure input port)
Pin configurations ....................... 3 = S (IR signal output), 4 = GND
IR output carrier frequency ........ 30 kHz to 1 MHz
General
Power input .................................. 100 VAC to 240 VAC, 50/60 Hz, 5 watts, internal, on 1 male IEC power connector
IPL T PC1 .......................... 12 A (max.)
IPL T PC1i ......................... 10 A (max.)
Temperature/humidity .............. Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
Cooling .......................................... Convection, unvented
1-2
IPL T PC1, IPL T PC1i Power Control • Specifications