beautypg.com

Electrolux EHG60412 User Manual

Page 7

background image

Important! The replacement of electric
cable must be carried out exclusively by the
service force centre or by personnel with
similar competencies, in accordance with
the current regulations.

Replacement of the connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make

sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown (or
black) phase wire.

Building In

min. 600 mm

min. 55 mm

min. 650 mm

550 mm

470 mm

min. 100 mm

30 mm

A

B

A - supplied seal
B - supplied brackets

Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be
easy to remove and let an easy access in
case a technical assistance intervention is
necessary.

min 20 mm

(max 150 mm)

30 mm

60 mm

b

a

a) Removable panel
b) Space for connections
Kitchen unit with oven
The hob recess dimensions must obey the
indication and the kitchen unit must be

equipped with vents to let a continuous
supply of air. The electrical connection of
the hob and the oven must be installed
separately for safety reasons and to let easy
remove oven from the unit.

50 cm2

360 cm2

180 cm2

120 cm2

MANUFACTURER:
ELECTROLUX ITALIA S.p.A.
C.so Lino Zanussi, 30
33080 PORCIA (PN) - ITALIA

electrolux 7