EARTHSTONE OVENS PRE-ASSEMBLED INSTALLATION INSTRUCTIONS---U.L. LISTED

17

Improper Installation (cont)

2) Oven is not closed to plenum/attic and is open to HVAC airflow.

Roof

Ceiling

Air flow

Air flow

Air flow

Installing a sealed enclosure around the oven
shell may cause improper operation by
starving the burner system of combustion air.
The air flow which travels above will cause
“negative pressure” below where the gas
burner is located. The air underneath will travel
towards the air flow above creating a suction
which will force the gas flame downwards. To
prevent this a non-combustable lid must be
placed above the oven.



3) Altered airflow from air intake in a separate room with low pressure.


Roof

Ceiling

Air flow

Air flow

Air Intake

Air Intake

Air flow

Air flow to oven is altered as air
moves from normal to low
pressure

Low pressure is created
by HVAC or any air moving
equipment outside oven
room

In this case the air intake located on the rear of the oven should be closed.