Operating Instructions
S
LIDER
/D
AMPER
S
ETTING
:
This is used to regulate the airflow through the pellet stove.
THE SLIDER / DAMPER MUST BE SET AT TIME OF INSTALLATION.
A Qualified Service Technician or Installer must set the Slider Damper.
• If the fire should happen to go out and the heat output indicator has been set on the lowest setting,
the Slider Damper should be moved to the left slightl, lessen the air flow into the firebox.
• If, after long periods of burning, the fire builds up and overflows the burn pot or there is a build up
of clinkers, this would be a sign that the pellet quality is poor, this requires more primary air, the slider
damper must be moved to the right to give the fire more air.
���� ���
���� ���
Figure 1: Slider / damper positions.
The easiest way to make sure that an efficient flame is achieved is to
understand the characteristics of the fire.
• A tall, lazy flame with dark orange tips requires more air – Push
Right
• A short, brisk flame, like a blowtorch, has too much air – Push
Left
• If the flame is in the middle of these two characteristics with a
bright yellow/orange, active flame with no black tips then the air is
set for proper operation.
6
C-10808
�
�
�
�
1. ON/OFF BUTTON: Used to turn the unit ON and OFF.
2. AUGER PULSE LIGHT: This light will flash in conjunction with the
auger.
3. HEAT OUTPUT INDICATOR: Shows the present heat output setting.
4. HEAT LEVEL ADJUSTMENT: When pressed, will change the heat
setting of the unit from low to high. the fan runs up and down with the
heat seting.
Notes:
• The convection blower speed will vary automatically with the feed rate.
• Due to varying fuel qualities this pellet stove may not operate on lower
Heat Level settings. If your unit goes out when on a low setting move the
heat level up to a higher setting.
• The lowest and highest heat levels on this pellet stove are used for
adjusting and accommodating for different pellet sizes and the varying
energy produced by the fuels. The size of the pellets will change the
volume of fuel being fed.
• The unit should be run at a setting where the least amount of cleaning of
the burn pot is needed.
The combustion exhaust blower is a variable speed blower controlled by the heat output setting. This
blower will increse or decrease the blower speed as the heat output setting is turned up or down.
SPECIAL NOTES:
Pellet quality is a major factor in how the pellet stove will operate. If the pellets have a high moisture
content or ash content the fire will be less efficient and has a higher possibility of the fire building up and
creating clinkers (hard ash build-up). If this happens, move the Slider / Damper to the right slightly to
increase the air flow to the fire.
S
TOVE
C
ONTROLS
:
Figure 3: Control panel.