9. Specifications
Electrical
Model
EATON ETN1000
EATON ETN2000
Nominal AC power
1000W
2000W
Max. AC power
(in 10 minutes)
1100W 2200W
Input
Nominal DCV
360V
DC
360V
DC
Max. open DCV
500V
DC
500V
DC
MPPT range
150 to 450V
DC
150 to 450V
DC
Working range
100 to 500V
DC
100 to 500V
DC
Max. input current
5A
DC
10A
DC
Output
Operational voltage
range
(F/W Setting)
206~264 V
AC
206~264 V
AC
Operational frequency
range
(F/W Setting)
49.25~50.75Hz
49.25~50.75Hz
Current distortion
<3%
<3%
Power factor
>0.99
>0.99
Maximum η
95%
96%
European η
93%
95%
Environment
Protection degree
IP 43
Operating temperature
-20 to 55ºC
Humidity
0 to 95%, non-condensing
Heat Dissipation
Convection
Power consumption
<7W
Acoustic noise
<35dBA
Communication & Features
LCD
1-Line, 16 characters
Comm. Interface
RS232 standard, RS485 optional
F/W upgrade
Yes, via RS232
Mechanical
W
×D×H (mm)
305x302x120
Weight (kg)
11.3
Normative references
Grid interface regulation
AS4777
Safety AS3100
EMC: EMS/EMI
EN 61000-6-2 (2005) / EN 61000-6-3 (2007)
CE
LVD: 2006/95/EC EMC: 2004/108/EC
1
Regulation voltage range is 200~270 V
AC
according to AS4777.
2
Regulation frequency range is 45~55Hz according to AS4777.