Inverter status, Display information – Eaton Electrical ETN2000 User Manual
Page 25
6. Inverter Status
Inverter is designed to be user-friendly. Therefore, the status of the Inverter
can be easily understood by reading the information that shown on the front
panel display. All possible messages are shown in the following table.
Display information
Operating conditions
In English
Description
Normal Working Status
Power off
No display
PV inverter is totally shutdown, V
PV
<70V
Standby
Standby
70V≦ Input voltage <100V
Initialization & waiting
Waiting
Input voltage range 100~150V during
start-up. After PV voltage is higher than
100V, inverter is waiting for feeding to grid
Check grid
Checking xxxS
When PV voltage> 150V, inverter is
checking feeding conditions
Feeding grid, MPPT
Normal
Inverter is feeding power. After 10 seconds
of this display, LCD will show wattage.
FLASH
FLASH
FLASH firmware
Monitoring Parameters
Instantaneous Output power
Pac =xxxx.xW
The real time output power in xxxx W
Accumulated energy
information
Eac=xxxxxxkWh
Total energy that has been fed to grid since
inverter was installed
Grid voltage
Vac = xxx.xV
Grid voltage in xxx.x VAC
Grid frequency
Frequency=xx.xHz
Grid frequency in xx.x Hz
Edition 1.6E, 2010/06