operAting the Device
DMM8 MANUAL
122
Step Description
1
Press the rotary knob of the required input
•
ROUTING TO OUT
is deactivated for the corresponding
input.
8.11
Activate/deactivate LOCKED
The following elements can be locked using the
LOCKED
function:
•
SYSTEM CONTROL
rotary knob
•
Complete unit
•
Individual channels
8.11.1 Locking the SYSTEM CONTROL rotary knob
To lock the
SYSTEM CONTROL
rotary knob, proceed as follows:
Step Description
1
Press the
SYSTEM CONTROL
rotary knob for longer than
3 seconds
• The
LOCKED
LED is lit.
• Turning the rotary knob has no function.
• All other rotary knobs are in
LEVEL
mode and can still be
operated.
8.11.2 Unlocking the SYSTEM CONTROL rotary knob
To unlock the
SYSTEM CONTROL
rotary knob, proceed as follows:
Step Description
1
Press the
SYSTEM CONTROL
rotary knob for longer than
3 seconds
• The rotary knob lock is removed.
• The
LOCKED
LED is no longer lit.
• The rotary knob is in the basic
LEVEL
position.
LOCKED
Lock rotary knob
Unlock rotary
knob