Mantel Clearances with Hood (Figure 5)

You must have non-combustible materials above the fireplace

opening. Non-combustible material must extend at least 8" above

fireplace opening. With sheet metal, you must have non-combustible

material behind it.
Heat resistant materials such as slate and marble must be at least

1/2" thick. Sheet metal should not be installed onto combustible

material.
Example: A mantel may project from the wall a maximum of 2" at

a minimum of 13-1/2" above the opening, and a maximum of 6"

at a minimum of 15" above the opening.

Figure 5

If your installation does not meet the above minimum clearances,

you must proceed to one of the following steps:

• Operate the heater with the flue damper open. See page 11 for

Installing as a Vented Appliance.

• Raise the mantel to the proper height.

• Remove the mantel.
Floor Clearance (Figure 6)

If installing heater at floor level, the minimum distance to com-

bustibles is “0” inches.

Figure 6

Sidewall & Ceiling Clearances (Figure 3)

Figure 3

The sides of the fireplace opening must be 6" from any combustible

wall. The ceiling must be at least 41" (for 18", 24" and 30" logs)

from the fireplace opening.
Mantel Clearances Without Hood (Figure 4)

You must have non-combustible materials above the fireplace

opening. Non-combustible material must extend at least 12"

above fireplace opening. With sheet metal, you must have non-

combustible material behind it.
Heat resistant materials such as slate and marble must be at least

1/2" thick. Sheet metal should not be installed onto combustible

material.

Figure 4

If your installation does not meet the above clearances, you must

proceed to one of the following steps:

• Use a hood.

• Operate the heater with flue damper open. See page 11 for Install-

ing as a Vented Appliance.

• Raise the mantel to the proper height.

• Remove the mantel.

Non-Combustible

Material Distance

Requirements for Safe Installation

12" or more

Non-combustible material

Less than 12"

Non-combustible material must be extended

to at least 8" with the installation of the

optional fireplace hood. If you cannot extend

non-combustible material at least 8", you must

operate heater with flue damper open.

CLEARANCES (continued)

18”, 24”, 30” Log

41”

6”

28”

12”

HEATER IN FIREPLACE

OR FIREBOX

HEAT RESISTANT

MATERIAL

12” WITHOUT

HOOD

10” and less Mantel

13.5”

14.25”

15.0”

16.0”

HOOD

HEATER IN

FIREPLACE

OR FIREBOX

HEAT RESISTANT

MATERIAL

8” WITH HOOD

8” Mantel

6” Mantel

4” Mantel

2” Mantel