WARNING

When used without adequate combustion and ventilation air, heater

may give off CARBON MONOXIDE, an odorless, poisonous gas.

Do not install heater until all necessary provisions are made for

combustion and ventilation air. Consult the written instructions

provided with the heater for information concerning combustion

and ventilation air. In the absence of instructions, refer to the

National Fuel Gas Code, ANSI Z223.1, Section 5.3 or applicable

local codes.

This heater is equipped with a PILOT LIGHT SAFETY SYSTEM

designed to turn off the heater if not enough fresh air is available.

DO NOT TAMPER WITH PILOT LIGHT SAFETY SYSTEM!

If heater shuts off, do not relight until you provide fresh air.

If heater keeps shutting off, have it serviced. Keep burner and control

compartment clean.

CARBON MONOXIDE POISONING MAY LEAD TO DEATH.

Early signs of carbon monoxide poisoning resemble the flu, with

headache, dizziness and/or nausea. If you have these signs, heater

may not be working properly. Get fresh air at once! Have heater

serviced.

Some people – pregnant women, persons with heart or lung disease,

anemia, those under the influence of alcohol, those at high altitudes

– are more affected by carbon monoxide than others.

The pilot light safety system senses the depletion of oxygen at its

location. If this heater is installed in a structure having a high vertical

dimension, the possibility exists that the oxygen supply at the higher

levels will be less than that at the heater. In this type of application,

a fan to circulate the structure air will minimize this effect. The use

of this fan will also improve the comfort level in the structure. When

a fan is used to circulate air, it should be located so that the air flow

is not directed at the burner.

• An unvented room heater having an input rating of more than

6,000 Btu per hour shall not be installed in a bathroom

• An unvented room heater having an input rating of more than

10,000 Btu per hour shall not be installed in a bedroom or bath-

room.

• Never burn solid fuels in a fireplace where a gas log set is in-

stalled.

• Due to high temperatures, the appliance should be located out of

traffic and away from furniture and draperies.

• Do not place clothing or other flammable material on or near the

appliance.

• Children and adults should be alerted to the hazards of high sur-

face temperature and should stay away to avoid burns or clothing

ignition.

• Young children should be carefully supervised when they are in

the same room as the appliance.

• This unit complies with ANSI Z21.11.2 Unvented Heaters and it

also complies with ANSI Z21.60 Decorative Vented Appliances for

Solid Fuel Burning Fireplaces. State or local codes may only allow

operation of this appliance in a vented configuration. Check your

state or local codes.

• Correct installation of logs, proper location of the heater and annual

cleaning are necessary to avoid potential problems with sooting.

Sooting, resulting from improper installation or operation, can

settle on surfaces outside the fireplace.

• Avoid any drafts that could alter burner flame patterns. Do not

allow fans to blow directly into the fireplace. Do not place a blower

inside burn box area of firebox. Ceiling fans may create drafts that

alter burner flame patterns. Sooting and improper burning will

occur as a result of drafts.

• WARNING: Do not allow fans to blow directly into the fireplace.

Avoid any drafts that alter burner flame patterns.

• WARNING: Do not use a blower insert, heat exchanger insert or

other accessory not approved for use with this heater.

• Periodic examination and cleaning of the venting system of the

solid-fuel burning fireplace, including frequency of such examination

and cleaning, by a qualified agency.

• The installation must conform with local codes or, in the absence

of local codes, with the National Fuel Gas Code, ANSI Z223.1/

NFPA54.

• NOTE: Installation and repair should be done by a qualified service

person. The appliance should be inspected before use and at least

annually by a qualified service person. More frequent cleaning may

be required due to excessive lint from carpeting, bedding material,

etc. It is imperative that the control compartment, burners and

circulating air passageways of the appliance be kept clean.

• Any safety screen or guard removed for servicing an appliance must

be replaced prior to operating the appliance. Provide adequate

combustion and ventilation air.

• The flow of combustion and ventilation air MUST NOT be ob-

structed.

• Provide adequate clearances around air openings into the combus-

tion chamber and adequate accessibility clearance for servicing

and proper operation. NEVER obstruct the front opening of the

appliance.

• An unvented room heater intended for installation in a solid-fuel

burning fireplace shall comply with the following instructions.

• A fireplace screen must be in place when the appliance is operating

and, unless other provisions for combustion air are provided, the

screen shall have an opening(s) for introduction of combustion

air.

• Solid-fuels shall not be burned in a masonry or UL 127 factory-built

fireplace in which an unvented room heater is installed.

• Any glass doors shall be fully opened when the appliance is in

operation.

• Any outside air ducts and/or ash dumps in the fireplace shall be

permanently closed at time of appliance installation.

• WARNING: Failure to keep the primary air opening(s) of the

burner(s) clean may result in sooting and property damage.

• WARNING: Before installing in a solid-fuel burning fireplace, the

chimney flue and firebox must be cleaned of soot, creosote, ashes

and loose paint by a qualified chimney cleaner.

IMPORTANT SAFETY INFORMATION