Empire Comfort Systems DVP48FP3 EN User Manual
Page 13
21759-6-0608
Page 13
Flush Wall Installation
Figure 12
Combustible Surround Installation
Figure 13
Vent Runs (Figures 14, 15, 16, 17 and 18)
In planning the installation for the fireplace, it is necessary to install
certain components before the appliance is completely positioned
and installed. These include the direct vent system, gas piping for the
appliance and the electrical wiring. (If the fan option is used.)
The appliance can be mounted on any of the following surfaces:
1. A flat, hard combustible (burnable) surface.
2. A raised wooden platform.
3. Four (4) corner supports. (Example: Four (4) concrete masonry
blocks.) These supports must be positioned so they contact all
four (4) perimeter edges on the bottom of the unit.
VERTICAL, 90° ELBOW WITH HORIZONTAL
TERMINATION
Figure 14
3! OF NON-COMBUSTIBLE MATERIAL
FINISHED WALL
FRONT TRIM OR NON-
COMBUSTIBLE MA TERIAL
(INSTALLA TION IS OPTIONAL)
JOINT BETWEEN FINISHED
WALL AND UNIT SEALED
WITH 300° F, 149° C SEALANT
MATERIAL (SEALANT IS OPTIONAL)
DVP42, 48
49 ½”(126 mm)
TO BOTTOM
OF UNIT
VENT CAP/
THIMBLE
3! OF NON-COMBUSTIBLE MATERIAL
FINISHED WALL
FRONT TRIM OR NON-COMBUSTIBLE
MATERIAL (INSTALLATION IS OPTIONAL)
JOINT BETWEEN FINISHED WALL AND
UNIT SEALED WITH 300° F 149
MATERIAL (SEALANT IS OPTIONAL)
° C
SEALANT
COMBUSTIBLE SURROUND
MANTELSHELF
2 X 4
HEADER
STAND OFF
/
THIMBLE
Attention: Cold climate installation recommendation:
When installing this unit against a non-insulated exterior
wall, it is recommended that the outer walls be insulated to
conform to applicable insulation codes.