beautypg.com

Time), Setting the encrypted transmission function, Encryption) – Sony ICD-PX470 Digital Voice Recorder with USB User Manual

Page 13: Low-cut filter setting, Power save setting, Setting the battery type, Displaying the accumulated use time

background image

13

Using wireless remote control, this function can be
controlled from the receiver and other devices.

For details on wireless remote control function, see
“Using the Cross Remote” on page 8.

Low-cut Filter Setting

(LCF)

The frequency of the low-cut filter can be set.

OFF:

Turns off the low-cut filter.

20 30 40 50 60 70 80 90 100
120 140 160 180 200 220 (Hz):

Low-cut filter is set

according to the selected frequency.

Using wireless remote control, this function can be
controlled from the receiver and other devices.

For details on wireless remote control function, see
“Using the Cross Remote” on page 8.

Power Save Setting

(POWER SAVE)

To conserve power, this setting allows you to put all
microphone functions to sleep.

ACTIVE:

The microphone operates normally.

SLEEP:

The sleep function is on. During sleep, the

POWER indicator flashes at 2-second intervals.

To change back to normal operation

During sleep, press the SET, +, or – button.

You can also use the wireless remote control to change the
receiver back to normal operation.

For details on wireless remote control function, see
“Using the Cross Remote” on page 8.

If the microphone is turned off while power save setting is
set to “SLEEP”, the setting will change to “ACTIVE”
automatically.

Setting the Battery Type

(BATTERY

TYPE)

Set this item according to the type of batteries you use to
obtain accurate battery power status indication.

TYPE1:

The power status is indicated based on

characteristics of new LR6 (size AA) Sony Alkaline
batteries. Select this for LR6 (size AA) alkaline batteries.

TYPE2:

Select this for rechargeable nickel-metal-hydride

batteries with capacities of about 2000 mAh.

TYPE3:

Select this for lithium batteries.

TYPE4:

Select this for rechargeable nickel-metal-hydride

batteries with capacities of about 2500 mAh.

The characteristics of batteries change according to battery
type and environmental conditions. It is recommended that
you learn the characteristics of batteries you use before
using them.

Displaying the Accumulated Use
Time

(TIME)

You can display the accumulated battery use time as a
rough estimate of total microphone usage.
The factory setting is “00:00”.

To reset the accumulated time indication

1

Hold down the SET button until the time indication
flashes.

2

Press the – button so “00:00 RESET” appears, and
then press the SET button.

Using wireless remote control, this function can be
controlled from the receiver and other devices.

For details on wireless remote control function, see
“Using the Cross Remote” on page 8.

Setting the Encrypted Transmission
Function

(ENCRYPTION)

You can set the encrypted transmission function.

SECURE KEY:

Sets the secure key method.

PASSWORD:

Sets the password method.

OFF:

The encrypted transmission function is not used.

For details, see “Using the Encrypted Transmission
Function” on page 9.

Input

Attenuation
(dB)

Reference
input level
(dBu)

Maximum
input level
(dBu)

Headroom
(dB)

MIC

0

–52

–16

36

3

–49

–13

6

–46

–10

9

–43

–7

3 dB steps

3 dB steps

3 dB steps

45

–7

+29

48

–4

+32

Note

Note

This manual is related to the following products: