7

E

Turning Power On/Off

Caution

• Turn on the monitor first before turning on the PC or

playback device.

Turning on the main power

Main power switch

Caution

• The main power must be turned on/off with the main power

switch. Do not connect/disconnect the power cord or turn

the breaker on/off while the main power switch is on.

• When switching the main power switch or the POWER

button off and back on, always wait for at least 5 seconds.

• For a complete electrical disconnection, pull out the main

plug.

Turning power on/off

Press the POWER button or POWER switch to turn the power

ON/OFF.

Power switch Power LED

Status

Status of the monitor

Green lit

Power on

Orange lit

Power off (Standby mode)

Green flashing

Input signal waiting mode

Accessing the operation panel

n

Mode setting

When the monitor is turned on for the first time after being shipped

from the factory, the mode setting screen will be displayed.

(1)Press

or

to select YES or NO.

(2)Press

ENTER

YES:

• OPERATION MODE is set to MODE1.

• OFF IF NO OPERATION is set to ON, and STANDBY

MODE is set to LOW POWER. (These settings can not be

changed.)

• If there is no operation for 4 hours or more, the monitor

automatically enters standby mode.

• Compared to when set to STANDARD, the current

consumption is reduced while the monitor is in standby

mode/input signal waiting mode, but the startup/return time

from standby mode/input signal waiting mode becomes

longer.

• While the monitor is in standby mode, control via LAN will

be disabled.

• While the monitor is in standby mode/input signal waiting

mode, only certain RS-232C commands can be used.

• Depending on the input signal, the monitor may not switch

to input signal waiting mode and may not return from input

signal waiting mode.

NO:

• OPERATION MODE is set to MODE2.

• OFF IF NO OPERATION is set to OFF, and STANDBY

MODE is set to STANDARD. (These settings can be

changed.)

• Compared to when set to LOW POWER, the startup/

return time from standby mode/input signal waiting mode

is reduced, but more power will be consumed in standby

mode/input signal waiting mode.

Even after being set, changes can be made using

OPERATION MODE, located in MONITOR menu.

n

Date/time setting

• If the time has yet to be set when the monitor is first turned

on, the date/time setting screen appears. Set the date and

time.

DATE/TIME SETTING

/

/

OK···[ENTER] CANCEL···[RETURN]

:

:

01

01

15

/

00

00

:

/ 20

1. Press

or

to select the date and time, and

press

or

to change the numerical values.

2. Press

ENTER

.

• Be sure to set the date and time.

• The date/time setting screen will close automatically if

no operation is performed for about 15 seconds. The

date and time can be set using DATE/TIME SETTING

from the SETUP menu when the date/time setting screen

disappears.

TIPS

Set the date in “Day/Month/Year” order.

Set the time on a 24-hour basis.

The clock is maintained by the internal battery.

If you already set the time but the date/time setting

screen appears when the power is turned on, the

internal battery may be exhausted. Please contact an

authorized SHARP servicing dealer or service center for

assistance with battery replacement.

Estimated service life of the internal battery: About 5

years (depending on monitor operation)

The initial battery was inserted at the factory when the

monitor was shipped, so it may run out of power before

its expected operation life.