Initial Installation

QUALIFIED INSTALLERS ONLY

C

ONVERTING

A D

IRECT

V

ENT

F

IREPLACE

T

O

A B-V

ENTED

F

IREPLACE

:

existing and attach with three (3) sheet metal screws evenly spaced to new 4’’ chimney connector.

5. Test fire the appliance and ensure proper operation. A venturi adjustment could be required to achieve

an efficient flame. Improper operation or adjustment could result in Carbon Monoxide production

causing personal injury or property damage.

C

ONVERTING

A B-V

ENT

F

IREPLACE

T

O

A D

IRECT

V

ENTED

F

IREPLACE

:

Chimney

Connector

Drafthood

Diverter

300°F (140°F)

Spill Switch

Air Channels (x2)

Parts required for conversion

1 - 300°F (149°C) manual reset spill switch

and wires

1 - Drafthood (4’’ chimney connection)

2 - Air channels

1 - Drafthood diverter
1. Remove the chimney connector, fresh air

cover plates and draft hood cover plate.

2. Install the 300°F (149°C) spill switch in the

location provided.

3. Install the two fresh air channels in the

correct locations.

4. Install a new 4’’ chimney liner into the

Drafthood

Cover Plate

Chimney

Connector

Air Channel

Cover Plate (x2)

Parts required for conversion

1 - Drafthood (2 - 3’’ dual pipe chimney

connector)

2 - Air channel cover plates

1 - Drafthood cover plate.
1. Remove the chimney connector, 300° spill

switch, two (2) B-vent air channels and B-

vent draft diverter plate.

2. Install the two (2) air channel cover plates in

the locations provided.

3. Install the draft hood cover plate in the

location provided.

4. Install two (2) 3’’ chimney liners in the

existing chimney, securing the 3’’ liners with

three (3) sheet metal screws evenly spaced

to the new chimney connector.

Figure 21: Converting To A BV Fireplace.

Figure 22: Converting To A DV Fireplace.

5. Test fire the appliance and ensure proper operation. A venturi adjustment could be required to achieve

an efficient flame. Improper operation or adjustment could result in Carbon Monoxide production

causing personal or property damage.