Setting Up Your Development Environment
MVI-ADMNET ♦ 'C' Programmable
Developer's Guide
'C' Programmable Application Development Module with Ethernet
Page 44 of 122
ProSoft Technology, Inc.
February 20, 2013
3.6.2 Connecting to the Module
To connect to the module’s Configuration/Debug port:
1
Connect your computer to the module’s port using a null modem cable.
2 Start the communication program on your computer and configure the
communication parameters with the following settings:
Baud Rate
19200
Parity
None
Data Bits
8
Stop Bits
1
Software Handshaking
None
3 Open the connection. Send the necessary command to terminate the
module’s program.
If there is no response from the module, follow these steps:
1 Verify that the null modem cable is connected properly between your
computer’s serial port and the module. A regular serial cable will not work.
2 Verify that your communication software is using the correct settings for baud
rate, parity and handshaking.
3 On computers with more than one serial port, verify that your communication
program is connected to the same port that is connected to the module.
4 If you are still not able to establish a connection, you can contact ProSoft
Technology Technical Support for further assistance.