Problem

Possible cause

Solution

The temperature regulator is not set
correctly.

Set a higher temperature.

Replacing the bulb

If you want to replace the bulb, do these steps:
1. Break the circuit of the appliance.
2. Unscrew the lamp cover securing screw.
3. Unhook the moving part by pressing it as shown in

the figure.

4. Replace the bulb with one of the same power (the

maximum power is shown on the light bulb cover)

5. Fix the lamp cover in place.
6. Screw the lamp cover securing screw.
7. Reconnect the appliance.
8. Open the door and check if the light comes on.

Closing the door

1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to "Installation".
3. If necessary, replace the defective door gaskets.

Contact the Service Center.

Technical data

ZKR1516

ZKR1506

ZKR1526

Dimension

Height

850 mm

850 mm

850 mm

Width

550 mm

550 mm

550 mm

Depth

612 mm

612 mm

612 mm

Rising Time

11 h

11 h

11 h

The technical information are situated in the rating plate
on the internal left side of the appliance and in the en-
ergy label.

Installation

Caution! Read the "Safety Information" carefully
for your safety and correct operation of the

appliance before installing the appliance.

Positioning

Install this appliance at a location where the ambient
temperature corresponds to the climate class indicated
on the rating plate of the appliance:

Climate

class

Ambient temperature

SN

+10°C to + 32°C

N

+16°C to + 32°C

ST

+16°C to + 38°C

T

+16°C to + 43°C