Amprobe TMA40 Airflow-Anemometer User Manual
Page 8
7
press nexT
•
press p-pg(previous page) or n-pg (next page) to see the previous or the next 100 points.
•
press bACK
•
press exiT to return to the main screen
•
COMPARISON TABLE
Measurement
Description
Memory Point
Single point
Single point measurement
no Memory
Multi-point
file name editable
Multi-point measurement
99 points
Automatic logging
programmable
data logging function
2400 points
Multi-point measurement
Data Logging
Record
99 points
2400 points
file name
editable or default with date
and time (note 1)
default (note 2)
Measuring/Sampling
press MeAS Key to measure
and store
Automatically measure and
store according to preset
parameters (note 3)
Note 1: The recording file name will show current date and time as file name if the user doesn’t
edit any.
example: ”05-06 09:21:51” means the recording was made on May 6th at 09:21:51 or June 5th
at 09:21:51 depending on your date mode setting.
Note 2: each recording file will take the current date and time as file name.
Note 3: The meter will start and stop recording at the preset dates and times. if the preset time
is less than 24-hour and the end date is in the future, the meter will stop at the ending time
and restart again the next day until the ending date or until the memory is full.
a) Set the date and start time
b) Set the date and stop time
c) Set the sample rate
d) in order to record 24-hour a day, you must set START for 00:00:00 and SUSpend for
23:59:59