9

Diode Check and Continuity

Resolution Accuracy

10 mV

±(1.5 % + 5 dgt)
From 0.4 V to 0.8 V

Max Test Current: 1.5 mA
Max Open Current: 3 V
Overload Protection: 1000 V dc/750 V ac
Continuity: Built-in buzzer sounds when resistance is less than

approximately 100

Ω. Response time is approximately 100 msec

DC

μA

Range Accuracy

400.0

μA

4000

μA

±(1.0 % + 2 dgt)


Voltage Burden:

< 5 mV/μA

Overload Protection: 1000 V dc/750 V ac
Resolution: 100 nA