beautypg.com

Ac voltage, Capacitance – Amprobe PM51A Pocket-Multimeter User Manual

Page 12

background image

10

AC Voltage

Range Accuracy

50 Hz – 60 Hz

4.000 V, 40.00 V, 400.0 V

±(2.0%+5 dgt)

60 Hz – 500 Hz

4.000 V, 40.00 V, 400.0 V

±(3.0%+5 dgt)

50 Hz – 500 Hz

600 V

±(3.5%+5 dgt)

Input Impedance: 10 M

Ω, 30 pF nominal

CMRR: > 60 dB @ DC to 60 Hz, Rs=1 k

Capacitance

Range

1

Accuracy

2

500.0 nF, 5.000

µF, 50.00 µF, 500.0 µF, 3000 µF

3

±.(3.5%+6 dgt

4

)

1

Additional 50.00 nF range accuracy is not specified

2

Accuracies with film capacitor or better.

3

Updates > 1 minute on large values

4

Specified with battery voltage above 2.8 V (half full battery). Accuracy decreases gradually to