Amprobe AM-60 Compact-Digital-Multimeter User Manual
Page 13

8
SPECIFICATIONS
General Specifications
Display :
2000 counts.
Polarity Indication :
Automatic, positive implied, negative
indicated.
Overrange Indication : “OL” or “-OL”.
Batteries Life :
Alkaline 250 hours
Low Batteries Indication : “N” is displayed when the batteries voltage
drops below operating voltage.
Auto Power Off :
Approx 10 minutes.
Operating Ambient :
Non-condensing ≦50°F, 51.8°F ~ 86°F
(≦80% R.H) 87.8°F ~ 104°F (≦75% R.H),
105.8°F ~ 122°F (≦45% R.H)
Storage Temperature : -4°F to 140°F , 0 to 80% R.H. when battery
removed from Meter.
Temperature Coefficient : 0.15 x (Spec. Accy) /°F ,< 64.4°F or >
82.4°F.
Measure :
Samples 2 times per second nominal.
Altitude :
6561.7 ft (2000m)
Safety :
Complies with EN61010-1, UL61010-1,
IEC 61010-1,
V/e :
CAT.III. 600V, CAT.II. 1000V.
A :
CAT.III. 500V
Pollution degree :
2
Power Requirements : 1.5V x 2 IEC LR03, AM4 or AAA size
Dimensions (W x H x D) : 74mm (2.9”) x 156mm (6.1”) x 44mm (1.7”)
Weight :
320g (0.71lb) including battery.
Accessories :
Battery (installed), Test leads and user manual.
Electrical Specifications
Accuracy is ±(% reading + number of digits) at 23°C ± 5°C < 80%RH.