beautypg.com

Amprobe ACD-50NAV ACD-51NAV ACDC-52NAV ACD-53NAV ACD-54NAV Navigator-Clamps User Manual

Page 32

background image

26

(9) Resistance & Continuity & Diode:

ACD-50NAV, ACD-51NAV, ACDC-52NAV, ACD-53NAV, ACDC-54NAV

Function

Range

Accuracy

Resistance

999.9 e

± (1.0% + 5dgt)

9.999 ke

± (1.0% + 3dgt)

99.99 ke

Continuity

999.9 e

± (1.0% + 5dgt)

Diode

0.40 ~ 0.80V

± (1.5% + 5dgt)

Overload protection : 1000Vrms
Max. Test Current : Approx. 0.5mA.
Maximum Open Circuit Voltage for e,

R

Approx. 3V

Maximum Open Circuit Voltage for diode : Approx. ±1.8V

Continuity check :
Internal sound activates if the resistance of the circuit under
test is less than 30e (approximately).
Continuity Indicator : 2 KHz Tone Buzzer

(10) Capacitance:

ACD-50NAV, ACD-51NAV, ACDC-52NAV, ACD-53NAV, ACDC-54NAV

Function

Range

Accuracy

Capacitance

3.999 μF

± (1.9% + 8dgt)

39.99 μF

399.9 μF

3999 μF

Overload protection : 1000Vrms

(11) Temperature :

ACD-51NAV, ACDC-54NAV

Function

Range

Accuracy

°C

-50 °C ~ 99.9 °C

± (1% + 2°C)

100 °C ~ 399.9 °C

400 °C ~ 1000 °C

± (1% + 1°C)

°F

-58 °F ~ 211.9 °F

± (1% + 4°F)

212.0 °F ~ 751.9 °F

752 °F ~ 1832 °F

± (1% + 2°F)

Overload protection : 1000 Vrms

• The above specification is assumed at the ambient temperature

stability within ±1°C. In addition, the temperature probe has
to be connected to meter for more than 1 hour before taking
measurement.

• The meter needs 2 hours for stability for ambient temperature

variation more than ±5°C.