Amprobe ACF-3000DM-A Current Transducer User Manual
Page 10
10
S P E C I F I C AT I O N S
Measuring Ranges:
300A/3000A
Output Sensitivity:
1mV/0.1mV/A (AC coupled)
Accuracy: (at 25°C)
±1% of range
Frequency Range:
10Hz to 5kHz
Phase Error:
±1º (45 to 65 Hz), ±10º (at 5 kHz)
L i n e a r i t y :
±0.2% of reading from 10% to 100% of range
Position Sensitivity:
±2% of range, cable >25mm (1”) from coupling
External Field:
±1% with cable >200mm (8”) from head
Minimum Load:
100kW for specified accuracy
Noise Level:
1.0mV rms (0.3% of range)
Operating Te m p e r a t u r e :
-20°C to 85°C (-4°F to 185°F) Electronics
Storage Te m p e r a t u r e :
-20°C to 85°C (-4°F to 185°F) Electronics
Gain Va r i a t i o n :
±0.08%/°C
Common Mode Vo l t a g e :
Voltage between the Output the Earth must not
exceed 30V
Power Supply:
2 x AA/MN1500 LR6 (1.5V) batteries
Battery Life:
4000 hours, 3000 hours typical (4 months cont.)
Low Battery Indication:
Red LED flashing
External Power:
Battery eliminator, via 2.1mm connector, 3V DC
Socket type A16M500
S a f e t y :
BS EN61010-1: 1993, 600V CATIII Pol. Deg 2
E M C :
EN61326: 1998
E n c l o s u r e :
IP5X, Flame retardant UL94-VO rated
M a t e r i a l :
Valox 357 X
Output Connections:
Hypotronics connector type DO1EEB306FST
We i g h t :
0.19 kg (0.4 lb)
Measuring Head
Cable length:
610mm (24 inches), double insulated
Cable Diameter:
14.3mm (0.562 inches)
Bend Radius:
38.1mm (1.5 inches) minimum
Connecting Cable:
2m (78.7 inches) long, double insulated
Material:
TPE rubber, Polypropylene, UL94-VO rated
Operating Temperature: -20°C to +90°C (-4°F to 194°F) Head
Storage Temperature:
-40°C to +105°C (-40°F to 221°F) Head
Safety:
BS EN 61010-1: 1993, 600V CAT III Pol. Deg 2
Weight:
0.18kg (0.4 lb)