beautypg.com

Aeroeffect, Usa s – MAAX APEX 108 9 FT User Manual

Page 12

background image

12

W

ater

heater

(

optIon

)

Available with whirlpool or combined

system only.

For electrical connection, refer to General

Information section in this guide and Fig.

4.

Make sure that the water heater pipe

connectors are firmly tightened (by hand

only).

This water heater is equipped with a

pressure interrupter and requires a

minimum of 10 gallons per minute water

circulation in order to function.

Note: The thermostat is pre-set and not

adjustable.

c

hromatherpy

l

IGht

WIth

a

Ir

p

ush

(o

ptIon

)

Not available with whirlpool or air

systems.

To ensure ventilation and easy servicing,

leave the light fixture free of fiberglass or

foam insulation, etc., on the underside of

the bathtub. (See Fig. 5a)

Press the air switch button to turn the

mood light on and off.

To change the light bulb, gently remove the

reflector from the underside of the bathtub.

The colored lenses are interchangeable.

c

hauffe

-

eau

(

optIon

)

Disponible avec système tourbillon ou

combo seulement.

Pour le raccordement électrique, se référer

aux ren seignements généraux au début de

ce guide et à la Fig. 4.

S’assurer que les raccords des tuyaux au

chauffe-eau sont bien serrés (à la main

seulement).

Ce chauffe-eau est muni d’un interrupteur

à pression et nécessite un minimum de

10 gallons par minute de circulation d’eau

pour fonctionner.

Note: Le thermostat est réglé à l’avance et

n’est pas ajustable.

l

umIère

de

chromothérapIe

avec

démarreur

à

pressIon

(

optIon

)

Non disponible avec les systèmes

tourbillon ou à air.

Pour faciliter le service et la ventilation,

ne pas obstruer la partie extérieure de la

lumière (laine minérale, mousse isolante,

etc.). Fig. 5a.

Actionner en appuyant sur le démarreur à

pression. Appuyer de nouveau pour éteindre.

Pour changer l’ampoule, retirez le réflecteur

en tirant doucement (par l’extérieur de la

baignoire).

Les lentilles de couleur fournies sont

c

alentador

de

aGua

(

opcIón

)

Disponible con sistema de hidromasaje

o combinado solamente.

Para la instalación eléctrica véase las

instrucciones generales al comienzo de

esta guía y la figura 4.

Cerciorarse de que las conexiones de la

tubería al calentador de agua están bien

apretadas (solamente con la mano).

Este calentador de agua está provisto de

un interruptor a presión y, para funcionar,

necesita como mínimo 10 galones de

circulación de agua por minuto.

Nota: El termostato está preprogramado y

no es ajustable.

l

uz

de

cromoterapIa

con

Interruptor

neumátIco

(

opcIón

)

No disponible con las sistemas de

hidromasaje o de aire.

Para facilitar la reparación y ventilación,

no obstruya la parte exterior de las luces

(tejido mineral, espuma aislante, etc.).

Fig. 5a.

Accionar pulsando sobre el interruptor a

presión. Pulsar de nuevo para apagar.

Para cambiar la lámpara, quite el reflector

tirando cuidadosamente (por el exterior de

la bañera).

Las lentes de color son intercambiables.

WATER HEATER

CHAUFFE-EAU

CALENTADOR DE AGUA

MOTOR

POMPE

BOMBA

GFCI

GFCI

ELECTRICAL

FEEDER

ALIMENTATION

ÉLECTRIQUE

SUMINISTRO

ELÉCTRICO

120V or/ou 220V

GFCI = Ground Fault Interruptor, Class A /

Disjoncteur de fuite à la terre, Classe A /

Interruptor para fallas a tierra, Clase A

GREEN / VERT / VERDE

WHITE / BLANC / BLANCO

BLACK / NOIR / NEGRO

GREEN / VERT / VERDE

WHITE / BLANC / BLANCO

BLACK / NOIR / NEGRO

Fig. 4

Note: This diagram can vary depending on the

system.

Note: Ce schéma peut varier selon le système.

Nota: Este esquema puede variar según el sistema.

BLOWER

SOUFFLEUR

SOPLADOR DE AIRE

B

B

B

BLOWER

SOUFFLEUR

SOPLADOR DE AIRE

BLOWER

SOUFFLEUR

SOPLADOR DE AIRE

BLOWER

SOUFFLEUR

SOPLADOR DE AIRE

BLOWER

SOUFFLEUR

SOPLADOR DE AIRE

B

RESET

TEST

GFCI

20 AMPS

GFCI

20 AMPS

NEMA

RESET

TEST

ELECTRICAL

FEEDER

ALIMENTATION

ÉLECTRIQUE

GFCI

SUMINISTRO

ELÉCTRICO

120V or/ou 220V

JUNCTION BOX*

BOÎTE DE JONCTION*

CAJA DE CONEXIONES*

GFCI

GFCI

PUMP

POMPE

BOMBA

P

CHROMATHERAPY LIGHT

LUMIÈRE DE CHROMOTHÉRAPIE

LUZ DE CROMOTERAPIA

(OPTION / OPCIÓN)

WATER HEATER

CHAUFFE-EAU

CALENTADOR DE AGUA

(OPTION / OPCIÓN)

ELECTRICAL

FEEDER

ALIMENTATION

ÉLECTRIQUE

SUMINISTRO

ELÉCTRICO

120V or/ou 220V

PUMP

POMPE

BOMBA

P

WATER HEATER

CHAUFFE-EAU

CALENTADOR DE AGUA

(OPTION / OPCIÓN)

AIR SWITCH

DÉMARREUR À AIR

INTERRUPTOR DE AIRE

AIR SWITCH

DÉMARREUR À AIR

INTERRUPTOR DE AIRE

RESET

TEST

GFCI

20 AMPS

GFCI

20 AMPS

NEMA

RESET

TEST

NEMA

NEMA

RESET

TEST

ELECTRICAL

FEEDER

ALIMENTATION

ÉLECTRIQUE

GFCI

SUMINISTRO

ELÉCTRICO

120V or/ou 220V

GFCI

GFCI

GFCI

PUMP

POMPE

BOMBA

P

WATER HEATER

CHAUFFE-EAU

CALENTADOR DE AGUA

(OPTION / OPCIÓN)

ELECTRICAL

FEEDER

ALIMENTATION

ÉLECTRIQUE

SUMINISTRO

ELÉCTRICO

120V or/ou 220V

PUMP

POMPE

BOMBA

P

AIR SWITCH

DÉMARREUR À AIR

INTERRUPTOR DE AIRE

B

ELECTRICAL

FEEDER

ALIMENTATION

ÉLECTRIQUE

SUMINISTRO

ELÉCTRICO

120V or/ou 220V

PUMP

POMPE

BOMBA

P

WATER HEATER

CHAUFFE-EAU

CALENTADOR DE AGUA

(OPTION / OPCIÓN)

AIR SWITCH

DÉMARREUR À AIR

INTERRUPTOR DE AIRE

AIR SWITCH

DÉMARREUR À AIR

INTERRUPTOR DE AIRE

RESET

TEST

NEMA

ELECTRICAL

FEEDER

ALIMENTATION

ÉLECTRIQUE

GFCI

SUMINISTRO

ELÉCTRICO

120V or/ou 220V

JUNCTION BOX*

BOÎTE DE JONCTION*

CAJA DE CONEXIONES*

GFCI

ELECTRICAL

FEEDER

ALIMENTATION

ÉLECTRIQUE

SUMINISTRO

ELÉCTRICO

120V or/ou 220V

AIR SWITCH

DÉMARREUR À AIR

INTERRUPTOR DE AIRE

AIR SWITCH

DÉMARREUR À AIR

INTERRUPTOR DE AIRE

JUNCTION BOX*

BOÎTE DE JONCTION*

CAJA DE CONEXIONES*

CHROMATHERAPY LIGHT

LUMIÈRE DE CHROMOTHÉRAPIE

LUZ DE CROMOTERAPIA

(OPTION / OPCIÓN)

CHROMATHERAPY LIGHT

LUMIÈRE DE CHROMOTHÉRAPIE

LUZ DE CROMOTERAPIA

(OPTION / OPCIÓN)

CHROMATHERAPY LIGHT

LUMIÈRE DE CHROMOTHÉRAPIE

LUZ DE CROMOTERAPIA

(OPTION / OPCIÓN)

CHROMATHERAPY LIGHT

LUMIÈRE DE CHROMOTHÉRAPIE

LUZ DE CROMOTERAPIA

(OPTION / OPCIÓN)

CHROMATHERAPY LIGHT

LUMIÈRE DE CHROMOTHÉRAPIE

LUZ DE CROMOTERAPIA

(OPTION / OPCIÓN)

CHROMATHERAPY LIGHT

LUMIÈRE DE CHROMOTHÉRAPIE

LUZ DE CROMOTERAPIA

(OPTION / OPCIÓN)

NEMA

GFCI

20 AMPS

GFCI

20 AMPS

NEMA

RESET

TEST

RESET

TEST

NEMA

GFCI

20 AMPS

GFCI

20 AMPS

BLOWER

SOUFFLEUR

SOPLADOR DE AIRE

B

ELECTRICAL

FEEDER

ALIMENTATION

ÉLECTRIQUE

SUMINISTRO

ELÉCTRICO

120V or/ou 220V

GFCI

PUMP

POMPE

BOMBA

P

WATER HEATER

CHAUFFE-EAU

CALENTADOR DE AGUA

(OPTION / OPCIÓN)

AIR SWITCH

DÉMARREUR À AIR

INTERRUPTOR DE AIRE

CHROMATHERAPY LIGHT

LUMIÈRE DE CHROMOTHÉRAPIE

LUZ DE CROMOTERAPIA

(OPTION / OPCIÓN)

JUNCTION BOX*

BOÎTE DE JONCTION*

CAJA DE CONEXIONES*

GFCI

GFCI

Fig. 3h

c

ombIned

W

hIrlpool

&

Aeroeffect

tM

system

W

Ith

W

ater

heater

(

optIon

) - usa

s

ystème

combo

t

ourbIllon

&

Aeroeffect

Mc

a

vec

c

hauffe

-

eau

(

optIon

) - é

tats

-u

nIs

s

Istema

combInado

de

hIdromasaje

y

Aeroeffect

Mr

c

on

c

alentador

de

aGua

(

opcIón

) - eu