beautypg.com

Summary of the faults, When first putting into service – DE DIETRICH DVC829WE1/XE1 User Manual

Page 23

background image

53

13/ IF OPERATING ANOMALIES OCCUR

EN

• SUMMARY OF THE FAULTS

Flashing LED(s)

for models without a display

Flashing LED(s)

d01 : water supply fault (tap)

d07 : overflow / anti-leak fault

d02 : draining fault

d08 : sprinkling distribution fault

d03 : heating fault

d11 : pressure sensor fault

➊➑

d04 : temperature fault

d12 : filling fault (water inlet

detection system)

d05 : fault – motor under load

d13 : overheating fault

➊➑

d06 : fault - motor overload

d14 : pump filling fault

• WHEN FIRST PUTTING INTO SERVICE

Problem

Possible

C

auses

What to do ?

The door falls heavily when
opened (integratable model)

- Door springs not tensioned

enough to compensate for the
weight of the panel.

- Tighten the two tensioning

screws accessible in the bot-
tom section above the front
feet.

The door does not stay horizontal
when open or returns too quickly
(integratable model)

- Door springs tensioned too

much.

- No wooden panel.

- Loosen the two tensioning

screws accessible in the bot-
tom section above the front
feet

- Fit a wooden panel on the

appliance (chipboard panel in
temporary) and adjust the
springs.

The door catches when closing - Appliance not stable

- Door not centred on the tub

- Adjust the feet.
- Re-centre by adjusting the

rear feet.

The upper basket does not stay
in the high position

- Poor manipulation (the basket

is being pulled upwards too
quickly)

- Act more progressively (see

instructions), one side and
then the other.

Small leak around or under the
appliance (move the appliance
to locate the leak better)

- Leak from the tap.

- Leak from the appliance.
(Cf. table fault d07).

- Check that a seal is fitted and

retighten the nut.

- Close the water tap and call a

technician.

Small leak at the door

- Appliance not stable or not level
- Door not centred on the tub.

- Adjust the feet.
- Re-centre by adjusting the rear

feet.