Summary of the faults, When first putting into service – DE DIETRICH DVC829WE1/XE1 User Manual
Page 23
53
13/ IF OPERATING ANOMALIES OCCUR
EN
• SUMMARY OF THE FAULTS
Flashing LED(s)
for models without a display
Flashing LED(s)
➊
d01 : water supply fault (tap)
d07 : overflow / anti-leak fault
➊
d02 : draining fault
d08 : sprinkling distribution fault
➑
➊
d03 : heating fault
d11 : pressure sensor fault
➊➑
d04 : temperature fault
d12 : filling fault (water inlet
detection system)
➑
➊
d05 : fault – motor under load
d13 : overheating fault
➊➑
d06 : fault - motor overload
d14 : pump filling fault
➑
• WHEN FIRST PUTTING INTO SERVICE
Problem
Possible
C
auses
What to do ?
The door falls heavily when
opened (integratable model)
- Door springs not tensioned
enough to compensate for the
weight of the panel.
- Tighten the two tensioning
screws accessible in the bot-
tom section above the front
feet.
The door does not stay horizontal
when open or returns too quickly
(integratable model)
- Door springs tensioned too
much.
- No wooden panel.
- Loosen the two tensioning
screws accessible in the bot-
tom section above the front
feet
- Fit a wooden panel on the
appliance (chipboard panel in
temporary) and adjust the
springs.
The door catches when closing - Appliance not stable
- Door not centred on the tub
- Adjust the feet.
- Re-centre by adjusting the
rear feet.
The upper basket does not stay
in the high position
- Poor manipulation (the basket
is being pulled upwards too
quickly)
- Act more progressively (see
instructions), one side and
then the other.
Small leak around or under the
appliance (move the appliance
to locate the leak better)
- Leak from the tap.
- Leak from the appliance.
(Cf. table fault d07).
- Check that a seal is fitted and
retighten the nut.
- Close the water tap and call a
technician.
Small leak at the door
- Appliance not stable or not level
- Door not centred on the tub.
- Adjust the feet.
- Re-centre by adjusting the rear
feet.