Filling the hydraulic reservoir – SAF-HOLLAND XL-TG10156UD TLV Series Liftgate User Manual
Page 14
14
XL-TG10156UD-en-US Rev A · 2013-04-18 · Amendments and errors reserved. © SAF-HOLLAND, Inc.
Filling the Hydraulic Reservoir
Figure 22
Figure 21
10. Filling the Hydraulic Reservoir
IMPORTANT: Keep dirt, water, and other contaminants
from entering the hydraulic system; clean
the area to prevent contamination of the
hydraulic fluid and use a clean funnel with
a fine screen mesh.
1. Set the vehicle parking brake.
2. Using the control station, put the platform in the down
and open position (Figure 21).
3. Remove the filler cap and add recommended hydraulic
fluid to pump reservoir. Check that the hydraulic fluid is
at the proper fill level, half full (Figure 22).
IMPORTANT: Always use the correct grade of hydraulic
fluid. Refer to the chart below for
recommended hydraulic fluid or contact
your SAF-HOLLAND representative.
TEMPERATURE
RECOMMENDED FLUIDS
RANGE
MANUFACTURER
TYPE
Above 0° C
(32° F)
Any
AW-32
ISO 32
-25 to 65° C
(-15 to 150° F)
Any Esso, Exxon
Mobil, Shell
HYDRAUL 50
DTE 11
DONAX TD
Low Viscosity
-35 to 50 ° C
(-30 to 120° F)
Exxon, Esso Shell,
Petro--Can
UNIVIS N15
TELLUS T15
MV ARCTIC 15
-45 to 40° C
(-50 to 100° F)
Any Esso, Exxon,
Shell
MIL-H-5606
UNIVIS J-13
UNIVIS HV1 13
FLUID #4
FILLER CAP
TLV MODEL IN
DOWN AND OPEN
POSITION