Displays – Purdy AND3222MST2 User Manual
Page 3

Purdy Electronics Corporation • 720 Palomar Avenue • Sunnyvale, CA 94085
7/20/07
Tel: 408.523.8200 • Fax: 408.733.1287 • [email protected]
3
www.purdyelectronics.com
Displays
Timing Chart
Timing Specifications
Item
Symbol
Min
Typ
Max
Unit
System Cycle Time
t
CVC
425
–
–
ns
Address Set-up Time
t
AW
30
–
–
ns
Address Hold Time
t
AH
10
–
–
ns
Data Set-up Time
t
DS
120
–
–
ns
Data Hold Time
t
DH
10
–
–
ns
Output Disable Time
t
OH
10
–
50
ns
AccessTime
t
ACC
–
–
120
ns
Enable Pulse Width
Read
t
EW
220
–
–
ns
Write
220
–
–
ns
Environmental Absolute Maximum Ratings
Item
Normal Temperature
Wide Temperature
Operating
Storage
Operating
Storage
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max
Ambient Temperature
0 ºC
+50 ºC
-20 ºC
+70 ºC
-20 ºC
+70 ºC
-30 ºC
+80 ºC
Humidity (without condensation)
See Notes 1, 3
See Notes 2, 4
See Notes 3, 4
See Notes 3, 5
NOTES:
1. Ta≤ 50 ºC: 80% RH max
Ta> 50 ºC: Absolute humidity must be lower than the humidity of 85%RH at 50 ºC
2. Ta at -20 ºC will be < 48 hrs at 0 ºC will be <120 hrs when humidity is higher than 75%.
3. Background color changes slightly depending on ambient temperature. This phenomenon is reversable.
4. Ta ≤ 70 ºC: 75RH max
Ta > 70 ºC: abosolute humidity must be lower than the humidity of 75%RH at 70 ºC.
5. Ta at -30 ºC will be <48hrs, at 80 ºC will be <120hrs when humidity is higher than 75%.
AND3222MST2