All installations and services must be performed by qualified service personnel.

78

XIV. APPENDIX E: TROUBLESHOOTING FLOWCHARTS

TURN THERMOSTAT TO CALL FOR HEAT

DOES THERMOSTAT MAKE CONTACT?

REPLACE BURNER

MOTOR

IS ROOM TEMPERATURE

BELOW THERMOSTAT SETTING?

IS THE OIL PUMP

MECHANICALLY

LOCKED-UP?

TURN T'STAT SETTING

ABOVE ROOM

TEMPERATURE

IS ROOM TEMPERATURE

No

No

REPLACE OIL PUMP

Yes

Yes

ALLOW THE ROOM

AIR TO COOL

No

IS VOLTAGE PRESENT

AT BURNER MOTOR?

No

Yes

Yes

Yes

IS THE BURNER

PRIMARY LOCKED
OUT ON SAFETY ?

No

No

Yes

No

CHECK FOR LINE VOLTAGE

@ FAN CONTROL MODULE.

IF NOT 115 VAC, CHECK FOR

BLOWN FUSE OR TURN ON

POWER. IF 115 VAC PRESENT,

CHECK OUT FAN CONTROL

MODULE & PRIMARY MODULE

ACCORDING TO MANUFACTURER'S

INSTRUCTIONS.

PUSH IN PRIMARY RESET BUTTON

IS BURNER MOTOR RESET

BUTTON POPPED OUT

DOES BURNER MOTOR

START?

PUSH IN MOTOR RESET BUTTON

CHECK IN PUT POWER,

DISCONNECTING SWITCH,

AND FUSE(S), IF EQUIPPED.

No

Yes

Yes