Thermo Pride OH5-85DE User Manual
Page 15
All installations and services must be performed by qualified service personnel.
OH5 2-STAGE
OH5 2-STAGE
CFM
Factory shipped
settings
G. ECM SPECIFIC REPLACEMENT PARTS
Part Name
OH5/OH2
OH11
OL5/OL2 OL11 OC5/OC2
OH5
2-STAGE
ECM Motor
AOPS7443/
AOPS7449
AOPS7444 AOPS7445/
AOPS7450
AOPS7446 AOPS7448/
AOPS7447
AOPS7454
Control
Board
350915 350915 350915 350915 350915 350184
Motor
Power
Harness
350917 350917 350918 350918 350917 350917
Motor
Control
Harness
350920 350920 350921 350921 350920 350183
Burner
Harness
350916 350916 350916 350916 350928 350182
Transformer
350464 350464 350464 350464 350464 350464
III. ECM TROUBLE SHOOTING
A. DIAGNOSTC FEATURES
The control board is equipped with 4 green Input Status LEDs and 1 red Board Status LED. These are intended to
provide a quick view into furnace performance without requiring a voltmeter.
The green Input Status LEDs are driven by the “Y”, “W”, “G”, and “DEHUM” inputs and are located directly
below those inputs. They will light to indicate the presence of these signals.
The red Board Status LED has two functions:
It will light when the board recognizes a valid input signal and will stay lit until all valid signals are removed.
This is intended to show that the board is functioning and able to respond to input signals.
It will flash rapidly while120VAC is missing from the LIMIT switch. This is intended to give a quick visual
indication of the High LIMIT switch.
SW1
SETTING TONS COOL LOW
SW1
LOW FIRE
HIGH FIRE
SETTING CFM RISE
CFM RISE
3 OFF
2 ON
6 OFF
5 OFF
4 ON
2 726 352
1 OFF
800 81
1008
78
3 OFF
2 ON
6 OFF
5 OFF
4 ON
2.5 924 462
1 ON
905
72
1121
70
3 ON
2 OFF
1 OFF
960 68
1200
66
6 OFF
5 ON
4 ON
3 1276 638
6 ON
5 OFF
4 OFF
3.5
1474
726
6 ON
5 OFF
4 ON
4 1600 814
13