beautypg.com

Thermo Pride Oil Furnace (general service and maintenance) User Manual

Page 15

background image

All installations and services must be performed by qualified service personnel.

13

TURN T'STAT SETTING

ABOVE ROOM TEMPERATURE

TURN THERMOSTAT TO CALL FOR HEAT

DOES THERMOSTAT MAKE CONTACT?

IS THE TRANSFORMER

SUPPLYING 24 VOLTS

TO THE THERMOSTAT

COOL THE THERMOSTAT

ARE WIRES CONNECTED

PROPERLY

REPLACE THERMOSTAT

CORRECT WIRE

CONNECTIONS

DOES BURNER MOTOR

START?

IS VOLTAGE PRESENT

AT BURNER MOTOR?

IS THE PRIMARY RELAY

LOCKED OUT ON SAFETY

CHECK CONTINUITY

OF WIRING

PUSH IN RESET BUTTON

IS MOTOR RESET

BUTTON POPPED OUT

IS THE OIL PUMP

FROZEN UP?

REPLACE BURNER

MOTOR

PUSH IN RESET BUTTON

REPLACE OIL PUMP

Yes

Yes

REPLACE TRANSFORMER

No

No

No

No

No

No

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

IS ROOM TEMPERATURE

BELOW THERMOSTAT SETTING?

No

No

No

No

Yes

No

CHECK INPUT POWER,

DOOR INTERLOCK,SERVICE

SWITCH AND FUSES

IS ROOM TEMPERATURE

ABOVE THERMOSTAT

SETTING?

IS THERE 120VAC

ACROSS THE PRIMARY

SIDE OF THE

TRANSFORMER?