beautypg.com

Thermo Pride Spirit Gas TG9S Single Stage PSC 95.5% User Manual

Page 20

background image

1083287-UIM-A-0114

20

Johnson Controls Unitary Products

FIGURE 26: Horizontal Left Configuration

HORIZONT

AL

- LEFT

INDUCER ROT

A

TED

HORIZONT

AL

- LEFT

INDUCER

AS RECEIVED

(Except for 130K Model)

AIRFLOW

AIRFLOW

Move pressure switch hose

to this position.

NOTE: May require the longer

hose that is provided with

wider cabinets

Move rain gutter hose to this position

NOTE: May require hose extension

that is provided with wider cabinets

Move rain gutter

hose to this position

Move pressure switch

hose to this position.

NOTE: May require

the longer hose that

is provided with

wider cabinets

Change condensate drain

connection to the 90° fitting provided

Move condensate

drain hose to this position

Move rain gutter hose

to this position.

NOTE: May require

hose extension that is

provided with wider

cabinets

Move

condensate

drain hose to

this position

Change condensate

drain connection to

the 90° fitting provided

When drain hose routing changes are required, be sure to cap all un-used openings.

If rerouting hoses - excess length should be cut of

f so that no sagging loops will collect

and hold condensate, which will cause the furnace to not operate.

1

2

3

4

5

3

4

1

2