Thermo Pride Air Handler Modular MV User Manual
Page 15

15
TABLE 15: Air Handler Air Flow Data
HIGH/LOW SPEED COOLING AND HEAT PUMP AIRFLOW
CFM
m³/min
JUMPER SETTINGS
12B
12D
12B
12D
High
Low
High
Low
High
Low
High
Low
COOL Tap
ADJ Tap
1385
896
1411
907
39.2
25.4
39.9
25.7
A
B
1137
745
1159
767
32.2
21.1
32.8
21.7
B
B
1203
777
1227
799
34.1
22.0
34.7
22.6
A
A
1019
650
1007
662
28.8
18.4
28.5
18.7
B
A
1085
690
1083
716
30.7
19.5
30.7
20.3
A
C
943
615
958
629
26.7
17.4
27.1
17.8
C
B
889
585
908
603
25.2
16.6
25.7
17.1
B
C
746
493
767
537
21.1
14.0
21.7
15.2
D
B
817
537
840
568
23.1
15.2
23.8
16.1
C
A
646
467
660
516
18.3
13.2
18.7
14.6
D
A
738
481
780
532
20.9
13.6
22.1
15.1
C
C
580
465
603
517
16.4
13.2
17.1
14.6
D
C
16C
20D
16C
20D
JUMPER SETTINGS
High
Low
High
Low
High
Low
High
Low
COOL Tap
ADJ Tap
2005
1433
2404
1579
56.8
40.6
68.1
44.7
A
B
1768
1145
2022
1313
50.1
32.4
57.2
37.2
B
B
2009
1299
2167
1388
56.9
36.8
61.3
39.3
A
A
1615
1040
1801
1159
45.7
29.4
51.0
32.8
B
A
1787
1159
1924
1256
50.6
32.8
54.5
35.6
A
C
1524
988
1818
1175
43.1
28.0
51.5
33.3
C
B
1445
940
1620
1024
40.9
26.6
45.9
29.0
B
C
1350
883
1638
1049
38.2
25.0
46.4
29.7
D
B
1384
906
1628
1030
39.2
25.6
46.1
29.2
C
A
1215
800
1442
929
34.4
22.6
40.8
26.3
D
A
1236
810
1434
911
35.0
22.9
40.6
25.8
C
C
1086
716
1305
859
30.7
20.3
36.9
24.3
D
C
HIGH / LOW SPEED ELECTRIC HEAT AIRFLOW
CFM
m³/min
JUMPER SETTINGS
12B
12D
12B
12D
High
Low
High
Low
High
Low
High
Low
HEAT Tap
ADJ Tap
1385
900
1411
913
39.2
25.5
39.9
25.8
A
N / A
1228
795
1258
817
34.8
22.5
35.6
23.1
B
N / A
1137
748
1159
769
32.2
21.2
32.8
21.8
C
N / A
917
603
928
619
26.0
17.1
26.3
17.5
D
N / A
16C
20D
16C
20D
JUMPER SETTINGS
High
Low
High
Low
High
Low
High
Low
HEAT Tap
ADJ Tap
2006
1411
2408
1515
56.8
39.9
68.2
42.9
A
N / A
1868
1243
2218
1285
52.9
35.2
62.8
36.4
B
N / A
1468
983
1902
1070
41.6
27.8
53.8
30.3
C
N / A
1248
840
1407
823
35.3
23.8
39.8
23.3
D
N / A
1. Airflow at nominal voltage, bottom return at 0.5 external static pressure, tested without filter installed, dry coil conditions.
2. These units have variable speed motors that automatically adjust to provide constant CFM from 0.0” to 0.6” w.c. static pressure.
3. From 0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static.
4. Operation on duct systems with greater than 1.0” w.c. external static pressure is not recommended.
5. Both the COOL and the ADJUST tap must be set to obtain the cooling airflow desired (CFM).
6. The ADJ tap does not affect the HEAT tap setting.
7. Low speed cooling used only with two stage outdoor units. (Speed is preset to 65% of high speed).
8. Dehumidification speed is 85% of jumper selected COOL tap and ADJUST tap.
9. When operating in both heat pump and electric heat modes, the airflow (CFM) will be per HEAT Tap CFM values only.
10. At some settings, LOW COOL and/or LOW HEAT airflow may be lower than what is required to operate an airflow switch on certain models of electronic air
cleaners. Consult the instructions for the electronic air cleaner for further details.
11. Airflow (CFM) indicator light (LED2) flashes once for every 100 CFM (i.e.: 12 Flashes is 1200 CFM) – blinks are approximate +/- 10% of actual CFM.