Rose Electronics CrystalView DVI Quad User Manual
Page 32

CRYSTALVIEW DVI QUAD INSTALLATION AND OPERATIONS MANUAL
28
Next Frame Switching (Receiver unit)
The moment of switching to the next frame is set for switch during HSYNC (Default setting). This can be
modified to switch during VSYNC by removing the jumper JP3 as shown in Figure 9 and Table 4.
To modify the next frame switching, first remove power from the Receiver unit. Next, remove the screws on
the bottom and sides of the Receiver chassis and carefully remove the top of the chassis exposing the circuit
boards. Locate the jumper JP3 as shown in figure 9. Set jumper JP3 as shown in Table 3.
JP3
Figure 9. Jumper Settings (Receiver unit)
Moment to switch
JP3
Switching during HSYNC (Default)
Switching during VSYNC
Table 4. Moment of switching jumper (Receiver unit)
Switching during HSYNC will have a higher frame rate but horizontal screen breaks may be detectable.
Switching during VSYNC has a lower frame rate with no horizontal screen breaks but stepping pictures are
possible.