Installation instructions, 7things you need to know, Getting things ready – Electrolux EOB 949 User Manual
Page 7
7
THINGS YOU NEED TO KNOW
WARNINGS:
· This appliance must be installed by a qualified
electrician/competent person. Safety may be
impaired if installation is not carried out in
accordance with these instructions.
· This appliance must be earthed.
· Do not remove the screws from the earth tab
extending from the oven mains terminal block
(Fig. 8).
· Before connecting the appliance make sure that
the voltage of your electricity supply is the same
as that indicated on the rating plate. This is
situated on the front frame of the appliance and
can be seen upon opening the door.
· Do not alter the electrical circuitry of this
appliance.
THINGS TO NOTE
· This appliance is designed to be fitted in cabinets
of the recommended dimensions as shown (Fig.3
and 4) without any modification to the cabinet.
· If your cabinet interior dimension is between 565-
570mm the oven may still be fitted. However, a
minor modification to the cabinet will be required.
· The dimensions given provide adequate air
circulation around the unit within the cabinet,
ensuring compliance with BS EN60-335.
· Enquiries regarding the installation of the cooker
point, if required, should be made to your
Regional Electricity Company to ensure
compliance with their regulations.
· The appliance socket switch should be outside
the cabinet but within 2m of the appliance to
make it accessible to switch off the appliance in
case of an emergency.
· To protect the hands, wear gloves when lifting
the oven into its housing.
NOTE: HOUSE CIRCUIT
Earth leakage and continuity tests must be carried
out before the appliance is connected to the mains
supply and re-checked after fitting.
GETTING THINGS READY
CHOICE OF ELECTRICAL CONNECTION
· There are two possible ways to connect your
appliance. Please choose from the most
appropriate after reading the descriptions.
a) It is recommended that this appliance is wired
with suitably rating cable (min 13 A), into fixed
wiring using a double pole isolator with a least
3mm contact separation in all poles and neutral,
located within 2m of the appliance. If this fixed
wiring circuit is only supplying the appliance, then
a fuse of 13A (or circuit breaker) should be
incorporated. When the circuit combines oven
and hob, then wire and fuse fuse rating should be
increased accordingly.
b) If you wish to connect an oven and a hob to a
cooker point you can:-
i. By connecting the appliance and hob
separately to the cooker point. Oven and hob
units should be separately connected to a
control panel. In this case the appliance
should be operated from 6mm² twin core, and
earth, PVC insulated multicore cable. See
Fig.1.
INSTALLATION INSTRUCTIONS
Subject to Regional Electricity Companies
regulations if you wish to connect the oven
and hob to the power supply you may use
one of the following two methods:-
Fig. 1