Troubleshooting – RISCO Group Industrial LuNAR User Manual
Page 23

Ind. LuNAR RK200DTG3 Installation
Guide
21
Troubleshooting
This section describes possible system problems and their solutions:
Always perform the following preliminary checks before referring to the troubleshooting table:
Perform a complete visual inspection of the Ind. LuNAR RK200DTG3, for signs of mechanical
damage, loose connections or torn wires.
Check the connections of the incoming AC power source.
Trouble
Meaning
Response
ProSYS Configuration of
detectors fails/not accepted by
the system
ID configuration
problem
Disconnect all power sources,
configure the desired IDs and
reconnect power again
Tamper indication while working
in the BUS mode
Tamper
connection
malfunction
Verify that both DIP 8 and 9 are in
ON position
Tamper indication in the Relay
or BUS mode
Tamper probably
not closed
Visually verify that ceiling tamper
and spring are correctly installed
Walk test cannot be initiated via
the ProSYS keypad
Wrong code
Insert the appropriate code
Green LED doesn’t operate
during Walk test - MW channel
does not function
Ind. LuNAR
RK200DTG3 is
configured (via
the ProSYS) to
the “MW disable
on DISARM”
during ProSYS’s
DISARM mode
Normal behavior
Ind. LuNAR
RK200DTG3
operating in
Bypass mode
due to “Bypass
MW channel
mode”
Reset the detector.
If MW channel trouble reoccurs,
replace the detector with a new one