PD8 Series Explosion-Proof Instrument Supplemental Manual
20
For Trident X2 Integrated Functionality Instruments
The ProtEX-MAX includes a removable screw terminal connector for external switch 
contacts. External switch contacts may be wired across the switch contact and COM 
on the connector labeled Trident X2 External Switch Connections in the Figure 
below. 
Figure 6: External Switch Contacts
(Trident X2 Integrated Instruments Only)
!
NOTICE
Removing the connectors or changing the default wiring of the 
ProtEX-MAX external switch connectors will affect the function of 
the SafeTouch buttons. 
See External Switch Contacts in the Specification on page 8 for electrical 
specifications for using the external switch contacts. 