beautypg.com

Consumption values, Hints for test institutes – Electrolux TK K2 E User Manual

Page 31

background image

Consumption values

The consumption values have been established under standard conditions. They
may deviate when the machine is operated in domestic circumstances.

Programme

Loading volume in kg

Energy consumption

in kWh

COTTON CUPBOARD
DRY

1)

Baumwolle

Schranktrocken

6

3.8

COTTON IRON DRY

1)

Baum-

wolle Bügeltrocken

6

3.0

SYNTHETICS CUPBOARD
DRY

2)

Mischgewebe

Schranktrocken

3

1.36

1) pre-drained at 1000 rpm
2) pre-drained at 1200 rpm

Hints for test institutes

Parameters possible to checked by the Test Institutes:
• Energy consumption (corrected with final humidity) during the cupboard dry cot-

ton cycle with nominal load.

• Energy consumption (corrected with final humidity) during the cupboard dry cot-

ton cycle with half load.

• Final humidity (during Cupboard dry cotton, Iron dry cotton and Cupboard dry

Easy care)

• Condensation efficiency (corrected with final humidity) during cupboard dry cot-

ton cycle with nominal and half load

All the cycles have to be checked in accordance with IEC 61121 (Tumble dryers for
household use – Methods for measuring the performance).

consumption values electrolux 31