Water hardness

Water contains, a varia-
ble quantity of limestone
and mineral salts of
which quantities vary ac-
cording to geographical
locations thus varying its
conductivity values.
Relevant variations of the
conductivity of the water
compared to those pre-
fixed by the factory could
slightly influence the
residual humidity of the
laundry at the end of the
cycle. Your dryer allows
you to regulate the
sensitivity of the drying
sensor based on
conductivity values of the
water.

1. Turn the programme selector to any pro-

gramme.

2. Press simultaneously the DELICATE Schon and

Start/Pause buttons and hold down for approx.
5 seconds. The current setting is shown by
lighting status diode:
– EMPTYING WATER TANK Behälter diode -

low conductivity <300 micro S/cm

– FILTER Sieb diode - medium conductivity

300-600 micro S/cm

– CONDENSER Wärmetauscher diode - high

conductivity >600 micro S/cm

3. Press the Start/Pause button sequentially until

you set desired level.

4. To memorize setting press simultaneously the

DELICATE Schon and Start/Pause buttons or
turn knob to OFF Aus position

28 electrolux machine settings