MEDC PAS2 User Manual
Page 3

12
© Cooper MEDC 2012
4. maIntenance
During the working life of the unit, little or no maintenance is required. However,
if abnormal or unusual environmental conditions occur due to plant damage or
accident etc., then visual inspection is recommended.
If a fault should occur, it is recommended that the unit be returned to MEDC for
repair. All parts are replaceable.
If you have acquired a significant quantity of units, it is recommended that spares
are also made available. Please discuss your requirements with the Technical
Sales Engineers at MEDC.
5. certIfIcatIon/approVals
Please refer to marking on the unit for specific approval details.
• UL listed for use in
Class I, Zone 1, AExd IIC T5.
USA (USL) and
Class I, Division 2, Groups A, B, C & D.
Canada (CNL)
Class II, Division 2, Groups F & G.
• UL Standards
UL 2279 & UL464.
• ULC Standards
CAN/ULC-S525-07
6. certIfIed temperature
–55°C to +70°C
–67°F to +158°F
11/
© Cooper MEDC 2012
General arranGement
All cable glands should be of an equivalent NEMA/IP rating to that of the unit
and integrated with the unit such that this rating is maintained.
Once termination is complete, carefully push the cover back onto the unit, avoid-
ing damage to the mating surfaces. Tighten the 6 off cover screws evenly, to
ensure maintenance of the required gap between the cover and enclosure.
3. operatIon
The unit is initiated directly from the power source.
For all versions, a 5-way DIL switch selects the tone required from the list shown.
The DB3P includes two 5-way DIL switches to select any two tones from the list.
These units can be switched between any two of the tones listed by either:-
· Reversing the polarity of the power supply, or
· By a 3 wire common +ve system, switching between the two –ve lines.
10
11
/
16
"
271mm
Ø 4
5
/
8
" / 117mm
Ø 6
11
/
16
" / 170mm
FIXING HOLE Ø
1
/
2
" /
FIXING HOLES Ø ALL
11
/
32
" / 9mm (2 POS.)
2 x
1
/
2
" NPT ENTRIES MAX
7
19
/
32
"
193mm
1
3
/
16
"
30mm
1
3
/
16
"
30mm
POSITION 2 IS USED IF ONLY 1 x
1
/
2
" NPT ENTRY REQUIRED
2
3
/
32
"
53mm
ALL DIMENSIONS IN INCHES AND MILLIMETERS