MEDC XB9 User Manual

Page 5

background image

© Cooper MEDC 2011

12/11

5.0 CERTIFICATION/APPROVALS

IECEx units

Certified to IEC60079-0 and IEC60079-1

Ex d unit (IEC certification No. IECEx BAS 10.0113)

Ex d IIC 5 (Tamb. -55°C to +55°C) Gb

T6 (Tamb. -55°C to +40°C) Gb

The IECEx certificate and product label carry the IECEx equipment protection level marking

Gb

Where Gb signifies suitability for use in a Zone 1 surface industries area in the presence of gas.

ATEX units

Certified to EN60079-0 and EN60079-1

Ex d unit (ATEX certification No. Baseefa00ATEX2031)

Ex d IIC T5 (Tamb. -55°C to +55°C) Gb

T6 (Tamb. -55°C to +40°C) Gb

The ATEX certificate and product label carry the ATEX group and category marking:

II 2 G

Where:

Signifies compliance with ATEX

II Signifies suitability for use in surface industries

2

Signifies suitability for use in a zone 1 area

G Signifies suitability for use in the presence of gases

The ATEX certificate and product label also carry the following mark:

This signifies unit compliance to the relevant European directives, in this case 94/9/EC, along with the number of

the notified body issuing the EC type examination certificate.

The ATEX and IECEx units also have the following EMC approvals

Conducted Emissions (DC) to EN61000-6-3:2007

Radiated Field Immunity (DC and AC) to EN61000-6-2:2005 / IEC61000-4-3:2002

Electrical Fast Transients/Bursts (DC and AC) to EN61000-6-2:2005 / IEC61000-4-4:2004

Surge Immunity (DC and AC) to EN61000-6-2:2005 / IEC61000-4-5:1995 + A1:2000

Mains Harmonics (AC) to EN61000-6-3:2007 / IEC61000-3-2:2006

Dips and Interruptions (AC) to EN61000-6-2:2005 / IEC61000-4-11:2004

T