Carefully replace the cover assembly back onto the base, avoiding damage to the mating surfaces. Replace the 6 off M8
screws (6.0mm A/F hexagon key) into the holes in the cover assembly and tighten evenly. Ensure the O-ring is seated
correctly on the cover during re-assembly. Ensure the required maximum gap of 0.2mm is maintained between the cover
and the base once assembled

5.0 CERTIFICATION/APPROVALS

IECEx units

Certified to IEC60079-0 and IEC60079-1

Ex d unit (IEC certification No. IECEx BAS 10.0094)

Ex d IIB T4 (-55°C to +85°C) Gb
T5 (-55°C to +55°C) Gb
T6 (-55°C to +40°C) Gb

The IECEx certificate and product label carry the IECEx equipment protection level marking

Gb

Where Gb signifies suitability for use in a Zone 1 surface industries area in the presence of gas.

ATEX units

Certified to EN60079-0 and EN60079-1

Ex d unit (ATEX certification No. BAS99ATEX2196)

Ex d IIB T4 (-55°C to +85°C) Gb
T5 (-55°C to +55°C) Gb
T6 (-55°C to +40°C) Gb

The ATEX certificate and product label carry the ATEX group and category marking:
II 2 G

Where:

Signifies compliance with ATEX

II Signifies suitability for use in surface industries

2 Signifies suitability for use in a zone 1 area

G Signifies suitability for use in the presence of gases

The ATEX certificate and product label also carry the following mark:

This signifies unit compliance to the relevant European directives, in this case 94/9/EC, along with the number of the
notified body issuing the EC type examination certificate.