Ensure the replacement bulb is of the correct fitment and carefully screw the new bulb into the holder. Take

care not to over-tighten the bulb. MEDC recommend that the replacement bulb should be suitable for ‘rough

service’ to ensure maximum life.

Carefully replace the cover assembly back onto the base, avoiding damage to the mating surfaces, and

ensuring the o-ring remains correctly seated in its groove during re-assembly. Fully tighten the 3 off M8

cover screws (6.0mm A/F hexagon key). Ensure the required gap (0.15mm max.) is maintained between

the cover and enclosure.

FL4 - Removing / Replacing Fluorescent Tubes

CAUTION: Before removing the cover assembly, ensure that the power to the unit is isolated.

NOTE: Some units will contain more than one fluorescent tube. It is advised that all the tubes should be

replaced at the same time. Tubes must be replaced with recommended types or compatible equivalents.

Failure to use a compatible tube may cause damage to the unit.

Tube Type: 13W - Osram DULUX D/E, GE BIAX D/E, Philips PL-C 4P or equivalent.

Tube Quantities: 13W unit = 1 X 13W tube

26W unit = 2 x 13W tubes

39W unit = 3 x 13W tubes

Unscrew the 3 off M8 screws (6.0mm A/F hexagon key) holding the cover assembly to the base. The cover

screws are captive and will be retained in the cover assembly.

Twist the cover assembly gently clockwise and anti-clockwise, whilst pulling it away from the base. Remove

to gain access to the interior. The cover will be remain attached to the base by means of a retention chain

Carefully grip the square base of the fluorescent tube and gently pull in an upwards direction until it is free

to be lifted away from the tube holder. Ensure the replacement tube is of the correct fitment. Line up the con-

necting pins on the tube with the holes in the tube holder and push firmly into position. Repeat the proce-

dure for each tube requiring replacement.

Carefully replace the cover assembly back onto the base, avoiding damage to the mating surfaces, and

ensuring the o-ring remains correctly seated in its groove during re-assembly. Fully tighten the 3 off M8

cover screws (6.0mm A/F hexagon key). Ensure the required gap (0.15mm max.) is maintained between

the cover and enclosure

5.0 CERTIFICATION/APPROVALS

IECEx units

Certified to IEC60079-0, IEC60079-1, IEC60079-7 and IEC60079-31

Ex d unit (IEC certification No. IECEx BAS 10.0078X)

FB4 units

60W versions:

Ex d IIC T4 (-55°C to +70°C) Gb

Ex td IIIC T135°C (-55°C to +70°C) Db IP6x

Ex d IIC T5 (-55°C to +30°C) Gb

Ex td IIIC T100°C (-55°C to +30°C) Db IP6x

100W versions:

MK6 terminals fitted:

12/10

© Cooper MEDC 2010