beautypg.com

Cleaning, Plug, Clean grass build-up under deck – Exmark METRO 21 MPKA21 User Manual

Page 32: Warning, Cleaning the discharge tunnel and plug, Maintenance

background image

Maintenance

Cleaning

Clean Grass Build-Up Under
Deck

Service Interval: Before each use or daily

1. Stop engine, wait for all moving parts to stop, and

remove spark plug wire.

2. To ensure the best performance, keep the

underside of the lawn mower housing clean
(Figure 32).

Figure 32

Blade Brake Unit Shown for Reference Only

Washing Method

1. Position the lawn mower on a flat concrete or

asphalt surface near a garden hose.

2. Start the engine.

3. Hold the running garden hose at handle level and

direct the water to flow on the ground just in
front of the right rear tire (Figure 33).

Figure 33

4. Engage the blade.

Note: The blade will draw in water and wash out
clippings. Let the water run until you no longer
see clippings being washed out from under the
housing.

5. Disengage the blade, stop the engine and wait for

all moving parts to stop.

6. Turn off the water.

7. Start the lawn mower, engage the blade, and let

the lawn mower run for a few minutes to dry out
its components.

Scraping Method

If washing does not remove all debris from under the
lawn mower, scrape it clean.

1. Disconnect the wire from the spark plug.

2. Drain the fuel from the fuel tank. Refer to

Emptying the Fuel Tank and Cleaning the
Fuel Filter
section.

WARNING

Tipping the lawn mower may cause the fuel
to leak from the carburetor or the fuel tank.
Gasoline is extremely flammable, highly
explosive, and under certain conditions, can
cause personal injury or property damage.

Avoid fuel spills by running the engine dry or
by removing the gasoline with a hand pump;
never siphon.

3. Tip the lawn mower onto its right side.

4. Remove the dirt and grass clippings with a

hardwood scraper. Avoid burrs and sharp edges.

5. Turn the lawn mower upright.

6. Fill the fuel tank.

7. Connect the wire to the spark plug.

Cleaning the Discharge
Tunnel and Plug

Service Interval: Before each use or daily

Always be sure that the discharge tunnel door closes
securely when you release the handle. If the debris
prevents the discharge door from closing securely,
clean the inside of the discharge tunnel and the door
thoroughly.

32