beautypg.com

Electrolux major appliances, n.a – Electrolux E30GC74GPS User Manual

Page 3

background image

Slide-In Cooktop / Downdraft Vent
Countertop Preparation Specifications

For detailed Slide-In Cooktop installation, refer to model-specific product
page and installation guide on web. Plan installation so that all required
minimum clearances between cooktop, overhead cabinets and adjacent
vertical walls are provided.

Position cooktop/vent cutout so all required minimum clearances are met.

Minimum flat countertop area must meet or exceed combined overall
width and depth as shown. Standard 25" countertop depth is NOT
adequate for slide-in cooktop / vent installations.

Separate circuits required for cooktop and vent. (Refer to product-specific
electrical specifications.)

Always consult local and /or national electric and gas codes. Check local
building codes for installation requirements, as they may vary per locale.

Proper combination installation will require 30" & 36" Gas Slide-In
Cooktop power cord to be relocated to underside of unit. (For details,
refer to 30" & 36" Gas Slide-In Cooktop Power Cord Relocation
Instructions on web.)

Downdraft Vent Specifications

For detailed Downdraft Vent installations, refer to model-specific
product page and installation guide on web.

Voltage Rating – 120V / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = 1.0 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded for
safe operation.)

Amps @ 120 Volts = 8.0 Amps

Vent unit outside of building only.

Vent must be installed in vertical orientation only.

1,600 CFM remote exhaust blower (PN # 5304444802) included with
vent – shipped in separate box.

Do not use flexible duct. Round duct instead of rectangular duct
recommended, especially when elbows are required.

When multiple elbows are necessary, ensure a minimum of 24" of straight
duct between any two elbows.

Thermal breaks such as short section of nonmetallic duct, should be
used in areas of extreme cold.

For most efficient airflow exhaust, use a straight run or as few elbows
as possible.

Cold weather installations should have additional backdraft damper
installed.

Installing a Downdraft Vent in combination with any gas cooking surface
will affect optimum burner efficiency.

Downdraft Vents can NOT be used in combination with any cooktop
backsplash.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at electroluxicon.com for detailed instructions.

High standards of quality at Electrolux Home Products, Inc. mean we are

constantly working to improve our products. We reserve the right to change

specifications or discontinue models without notice.

Electrolux Major Appliances, N.A.

USA

250 Bobby Jones Expressway

Augusta, GA 30907

1-877-4electrolux (1-877-435-3287)

electroluxicon.com

CANADA

5855 Terry Fox Way

Mississauga, ON L5V 3E4

1-800-265-8352

electroluxicon.ca

SIC_DDV_PREP 01/09

© 2009 Electrolux Home Products, Inc.

Printed in the U.S.A.

Countertop Preparation for 30" & 36" Slide-In Cooktop / Downdraft Vent Installation

Cooktop Installation Note:
To ensure proper installation, refer to model-specific installation
guide on web for cooktop dimensions, cutout dimensions and
cabinet requirements.

Countertop Preparation Note:
Countertop with backsplash may not allow enough flat area for
proper installation, 2-13/16" of flat countertop required behind
cooktop. No gap required between back of cooktop and front
of downdraft trim piece.

*Standard 25" countertop depth is NOT adequate for slide-in

cooktop / vent installations.

Stiffener

Back side of

cabinet front

Vent unit

Downdraft
chimney top

Slide-In Cooktop

25

13

/

16

"

End of cooktop
support platform

Countertop*

2

13

/

16

"

3"

Vertical noncombustible surface - rear wall

Studwall

1

/

4

" min. flat ledge

1

15

/

16

"

9

/

32

"

E36DD75ESS / 36" Cooktop Cutout Dimensions

36" Cooktops

A

B

C

D

E

E36EC75DSS

35

15

/

16

" 35

3

/

16

"

22"

25

13

/

16

" 33

3

/

4

"

E36EC75ESS

35

15

/

16

" 35

3

/

16

"

22"

25

13

/

16

" 33

3

/

4

"

E36EC75HSS

35

15

/

16

" 35

3

/

16

"

22"

25

13

/

16

" 33

3

/

4

"

E36GC75DSS* 35

15

/

16

" 35

3

/

16

"

22"

25

13

/

16

" 33

3

/

4

"

E36GC75ESS*

35

15

/

16

" 35

3

/

16

"

22"

25

13

/

16

" 33

3

/

4

"

E36GC75GSS*

35

15

/

16

" 35

3

/

16

"

22"

25

13

/

16

" 33

3

/

4

"

E36GC76EPS*

35

15

/

16

" 35

3

/

16

"

22"

25

13

/

16

" 33

3

/

4

"

E36GC76GPS*

35

15

/

16

" 35

3

/

16

"

22"

25

13

/

16

" 33

3

/

4

"

E30DD75ESS / 30" Cooktop Cutout Dimensions

30" Cooktop

A

B

C

D

E

E30GC74GPS*

29

15

/

16

" 29

3

/

16

"

22"

25

13

/

16

" 27

3

/

4

"

*Proper combination installation will require cooktop power cord

to be relocated to underside of unit.

(For details, refer to 30" & 36"

Gas Slide-In Cooktop Power Cord Relocation Instructions page.)

For detailed cooktop and
downdraft vent installation
specifications, refer to
model-specific product
page and installation
guide on web

7

1

/

4

"

1

/

4

" min.

flat ledge

Downdraft vent cutout opening
in cooktop support platform

B

A

1" countertop
overhang

C

2

9

/

16

"

7

1

/

2

"

E

D

Slide-In Cooktop/Downdraft Vent
Countertop Preparation