SKT 2300 A1

9

After a short time the temperature display
stops flashing and switches to the measured
value.

Note:

The temperature is measured at the

appliance. It might be some time before the
entire room has also reached this
temperature.
As soon as the set temperature is reached,
the heating function switches off
automatically and the indicator lights

19

for

the heat settings flash. As soon as the
temperature falls below the desired
temperature, the heating function
automatically switches on again and the
indicator lights

19

for the heat settings are

constantly illuminated.

5.3 Setting the heat setting

The appliance has three heat settings:

– 1,000 watts
– 1,300 watts
– 2,300 watts

1. Press button

17

repeatedly until the

desired heat setting is set.
The relevant indicator light 19 lights up.
Notes:
– if both indicator lights 19 are

illuminated, the 2,300 watts heat
setting has been selected,

– if no indicator light 19 is illuminated,

the heating function is switched off,

– if the indicator lights 19 flash, the

desired temperature has been
reached.

2. Press the fan button 16 to switch the fan

on or off.
When the fan is switched on, the
indicator light 14 lights up.
Note:

The fan might make a slight noise,

but it does ensure better circulation of
the heated air.

5.4 Setting the heating time

The appliance has a timer for setting the
heating time to between 1 and 15 hours.
The appliance switches off automatically
once the heating time has expired.
1. Press the timer button 11 repeatedly until

the desired number of hours is indicated
by the indicator lights 10.
Note:

You will need to add together the

number of hours indicated by the
indicator lights 10. If, for example, 2H
and 8H are lit up, the heating time is 10
hours.

2. To switch off the timer, press the timer

button 11 repeatedly until none of the
indicator lights 10 is illuminated.

5.5 Thermal cut-out

For your safety the appliance has a thermal
cut-out.
If the temperature inside the appliance
becomes too high, the appliance switches
off automatically:
1. Switch the mains switch 8 to 0FF to

switch off the appliance.

2. Check whether the air inlet 6 or outlet 4

is obstructed and remove the cause.
If you cannot establish a cause and the
fault occurs repeatedly, have the
appliance repaired or else take it out of
use.

3. Wait for the appliance to cool down.
4. You can then continue to operate it

normally.