Mounting, Adjusting the lamp, Changing the bulb – Livarno HALOGEN CEILING LIGHT User Manual
Page 32
32 GB
Prior to installation / Mounting / Adjusting the lamp / Changing the bulb
person must be familiar with the characteristics of
the luminaire and connection regulations.
Familiarise yourself with all instructions and
diagrams in this manual, as well as with the
luminaire before installation.
Before installation, ensure that the cable that the
luminaire will be attached to is de-energised.
To do this, remove the fuse or switch off the
circuit breaker in the fuse box (0 position).
Use the voltage tester to verify de-energised
status.
Mounting
Fix the chrome-plastic decorative rings
1
to
the smooth side of the glass plate
4
by press-
ing them into the intended opening in the glass
plate
4
.
Remove the fixing screw
2
and the washer
3
from the luminaire body.
Position the glass plate
4
on the holder and
washers provided and mount with the aid of
washer
3
and fixing screw
2
(see fig.).
Remove the visible screws
8
on the side of the
connection housing
10
and take off the mount-
ing bracket
6
on the rear (see fig.).
Use the slotted holes intended for the mounting
bracket
6
to mark the bores.
Drill the fastening bores (∅ approx. 6 mm, depth
approx. 40 mm). Ensure that you do not damage
the supply line.
Introduce the dowels
7
into the bores. Fasten
the mounting bracket
6
with the provided
screws
9
.
Now connect the connection cable of the light
to the mains connection cable (external)
13
by
means of the terminal block
12
provided.
Note: Ensure that each wire of the mains con-
nection cable (external) is properly connected
in the correct place: live wire, black or brown =
symbol L, neutral wire, blue = symbol N, pro-
tective earth wire, green-yellow = symbol .
Use the screws
9
to fasten the luminaire to
the mounting bracket
6
.
Use a clean, lint-free cloth to insert a bulb
14
.
insert the new bulb
14
into the socket carefully
and tighten it with a ¼ turn.
Check for correct fitting.
Attach the chrome-plastic decorative ring
15
carefully to the bulb
14
of the movable spot-
light
11
.
Your luminaire is now ready for operation.
Adjusting the lamp
Note: Only change the alignment of the light
when it is switched off.
Allow the luminaire to cool completely.
Turn the individual spotlights
11
in the desired
direction.
Tilt the individual spotlights
11
to the desired
angle.
Afterwards, check that the spotlights
11
are
firmly in place.
Changing the bulb
CAUTION! DANGER OF ELECTRIC
SHOCK! To replace the bulb, first disconnect the
luminaire from the mains circuit. To do this, remove
the fuse or switch off the circuit breaker in the fuse
box (0 position).
CAUTION! DANGER OF BURN INJURIES!
Allow the luminaire to cool completely.
Replace the bulb
14
only after it has fully cooled.
Remove the chrome-plastic decorative ring
15
from the bulb
14
.
Use a clean, lint-free cloth to replace a bulb.
Remove the defective bulb
14
carefully out of
the socket.
Only use 220–240 V ∼ eco halogen light
bulbs with a GU 10 base and a maximum of
28 Watts.
Insert the new bulb
14
into the socket. Check