- 35 -
?
Return the value of default S register.
T
Force DTMF dialing.
V0
Report short form (terse) result codes.
V1
Report long form (verbose) result codes.
W0
Report DTE speed in EC mode.
W1
Report line speed, EC protocol and DTE speed.
W2
Report DCE speed in EC mode.
X0
Report basic call progress result codes, i.e., OK, CONNECT, RING, NO CARRIER (also, for busy, if enabled, and dial tone not detected), NO ANSWER and ERROR.
X1
Report basic call progress result codes and connections speeds (OK, CONNECT, RING, NO CARRIER (also, for busy, if enabled, and dial tone not detected), NO ANSWER,
CONNECT XXXX, and ERROR.
X2
Report basic call progress result codes and connections speeds, i.e., OK, CONNECT, RING, NO CARRIER (also, for busy, if enabled, and dial tone not detected), NO
ANSWER, CONNECT XXXX, and ERROR.
X3
Report basic call progress result codes and connection rate, i.e., OK, CONNECT, RING, NO CARRIER, NO ANSWER, CONNECT XXXX, BUSY, and ERROR.
X4
Report all call progress result codes and connection rate, i.e., OK, CONNECT, RING, NO CARRIER, NO ANSWER, CONNECT XXXX, BUSY, NO DIAL TONE and ERROR.
Y0
Disable long space disconnect before on-hook.
Y1
Enable long space disconnect before on-hook.
Z0
Restore stored profile 0 after warm reset.
Z1
Restore stored profile 1 after warm reset.
&C0
Force RLSD active regardless of the carrier state.
&C1
Allow RLSD to follow the carrier state.
&D0
Interpret DTR ON-to-OFF transition per &Qn.
&D1
Interpret DTR ON-to-OFF transition per &Qn.
&D2
Interpret DTR ON-to-OFF transition per &Qn.
&D3
Interpret DTR ON-to-OFF transition per &Qn.
&F
Recall (restore) factory profile.
&G0
Disable guard tone.
&G1
Disable guard tone.
&G2
Enable 1800 Hz guard tone.
&J0
Set S register response only for compatibility.
&J1
Set S register response only for compatibility.
&K0
Disable DTE/DCE flow control.
&K3
Enable RTS/CTS DTE/DCE flow control.
&K4
Enable XON/XOFF DTE/DCE flow control.
&L0
Select dial up line operation.
&L1
Select leased line operation.
&M0
Select direct asynchronous mode.
&M1
Select sync connect with async off-line command mode.
&M2
Select sync connect with async off-line command mode and enable DTR dialing of directory zero.
&M3
Select sync connect with async off-line command mode and enable DTR to act as Talk/Data switch.
&P0
Set 10 pps pulse dial with 39%/61% make/break.
&P1
Set 10 pps pulse dial with 33%/67% make/break.
&P2
Set 20 pps pulse dial with 39%/61% make/break.
&P3
Set 20 pps pulse dial with 33%/67% make/break.
&Q0
Select direct asynchronous mode.
&Q1
Select sync connect with async off-line command mode.
&Q2
Select sync connect with async off-line command mode and enable DTR dialing of directory zero.
&Q3
Select sync connect with async off-line command mode and enable DTR to act as Talk/Data switch.
&Q4
Select Hayes AutoSync mode.
&Q5
Modem negotiates an error corrected link.
&Q6
Select asynchronous operation in normal mode.