20 GB
Before installation / Preparations for use
Before installation
Important: The electrical connection must be
carried out by a qualified electrician or someone
trained to perform electrical installations. This person
must be familiar with the properties of the light and
all connection regulations.
Familiarise yourself with all instructions and
diagrams in this manual as well as with the
light before installation.
Before installation, ensure that the cable that
the light is to be attached to is not live. To do
this, remove the fuse or switch off the circuit
breaker in the fuse box (0 position).
Use the voltage tester to check that there is
no voltage.
Preparations for use
Mounting the light
Note: you will need a drill for installation.
CAUTION! RISK OF INJURY! Refer to your
drill's operating instructions.
Remove both bulbs
1
. Remove the respective
light bulb
1
by turning it a ¼ turn and pulling
it out of the socket. Use a clean, lint-free cloth
when you are replacing a bulb.
Remove the metal cover
7
, releasing it by
pressing it lightly out of the fastening.
Note: release the metal cover
7
carefully as
this is connected with the protective earth cable
of the light by means of a screw.
Hold the light on the required position on the
ceiling.
Mark the drill holes for the installation openings
8
(see fig. B).
Drill the holes (ø approx. 6 mm, depth approx.
40 mm). Make sure that no electrical wiring is
damaged during this operation.
Insert the dowels in the drilled holes. Use a
hammer if necessary.
Insert the supplied screws into the dowels and
let them project a distance of about 2.0 mm
from the ceiling or mounting surface.
Route the mains connection cable (external)
3
through the designed opening
9
.
Insert the screws into the relevant mounting
openings
8
of the light and align the light by
pushing it to the left or to the right. Finally tighten
the screws.
Now connect the connection cable of the light
to the mains connection cable (external)
3
by
means of the terminal block
4
provided.
Note: Ensure that each wire of the mains
connection cable (external) is properly con-
nected in the correct place: live wire, black or
brown = symbol L, neutral wire, blue = symbol N,
protective earth wire, green-yellow = symbol .
Replace the metal cover
7
by lightly pressing
on the light base
5
. Ensure that the notches
6
of the metal cover
7
lock into place in the
catches
2
of the light base
5
. Check for
correct fitting.
Insert the two bulbs
1
once again. Insert each
bulb
1
into the socket and tighten it with a
¼ turn. Check for correct fitting.
Reinsert the fuse or switch the circuit breaker
back on.
Your light is now ready for operation.
Replacing a bulb
CAUTION! RISK OF ELECTRIC SHOCK!
To replace the bulb, first of all disconnect the light
from the mains circuit. To do this, remove the fuse
or switch off the circuit breaker in the fuse box
(0 position).
CAUTION! RISK OF BURNS! Allow the
lamp to cool down completely.
Replace the bulb
1
only after it has fully
cooled. Use a clean, fluff-free cloth when you
are replacing a bulb.
Remove the bulb
1
by turning it a ¼ turn and
pulling it out of the socket.
insert the new bulb
1
into the socket and tighten