beautypg.com

Installation, Caution – Electrolux Ice Maker 241927600 User Manual

Page 5

background image

5

Installation

Installation Dimensions

Installing the Drain

CAUTION

PLEASE READ all instructions completely
before attempting to install or operate the unit.
All ice makers require a connection to the
water supply and improper hook-up can result
in substantial property damage! All water
and drain connections MUST BE made by a
licensed/qualified plumbing contractor. Failure
to follow recommendations and instructions
may result in damage and/or harm.

CAUTION

Plumbing installation must observe all
state and local codes. All water and drain
connections MUST BE made by a licensed/
qualified plumbing contractor. Failure to follow
recommendations and instructions may result
in damage and/or harm.

Model EI15IM55GS can be installed using a gravity
drain or the Electrolux EIMP60, optional drain
pump kit.

Follow these guidelines when installing drain lines
to prevent water from flowing back into the ice
maker storage bin and/or potentially flowing onto
the floor causing water damage:

Gravity Drain

• Drain lines must have a 5/8 inch inside

diameter.

• Drain lines must have a 1 inch drop per 48

inches of run (1/4 inch per foot) and must not
create traps.

• The floor drain must be large enough to

accommodate drainage from all drains.

• Insulate the bin drain line to prevent

condensation.

14 - 15/16”

(37.9)

24”

(61)

5”

(12.7)

21 - 3/4”

(55.2)

34 - 1/8”

(86.7)
FULL

RETRACT

HEIGHT

WATER

VALVE

WATER

OUTLET

WATER

DRAIN

Figure 1