Operation, Ice cube thickness adjustment, Important – Electrolux Ice Maker 241927600 User Manual
Page 15
15
Operation
Ice Cube Thickness Adjustment
Interval - As Required
Ice thickness adjustments are made using the
control panel as follows:
IMPORTANT
Ice thickness adjustment should only be made
one increment at a time. Allow ice maker
production to stabilize for 24 hours before
rechecking ice thickness.
3.
Touch and release the LIGHT button key to
exit the ice thickness adjustment mode.
4.
Remove all ice from the storage bin.
5.
Ice cubes in any given batch will vary, so
it is necessary to choose cubes from the
sample area (Figure 28) for comparison
when making adjustments. If further
adjustments are desired, repeat steps 1
through 4.
1. To enter the thickness adjustment mode:
a. Touch and hold the UP ARROW button.
b. Touch and release the DOWN ARROW
button three times, then release the UP
ARROW button.
c. The display will switch to “0,” to confirm
the thickness adjustment mode has
been selected.
2.
The factory setting is “0,” and the total
range of adjustment is -5 to +5. Use the
UP ARROW button to raise the setting
and thicken the ice bridge, or the DOWN
ARROW button to lower the setting to thin
the ice bridge.
IMPORTANT
It is extremely important that Clear Ice models are
level. If not level, the ice mold will not fill evenly.
SAMPLE AREA
ICE005
Figure 28
ICE
POWER
DOWN
ARROW
LIGHT,
BLACKOUT MODE
& OTHER FUNCTIONS
DISPLAY
UP
ARROW
Figure 27