beautypg.com

Fig.5 fig.6 fig.7, Troubleshooting, Spray calibration – Sealey SSA2 User Manual

Page 3

background image

5.2

Broadcast Nozzle

5.2.1 If needed, rotate the broadcast nozzle so that the spray

pattern is pointing down and evenly distributed. (fig.5)

5.2.2 Ensure gloves are worn when adjusting the lance and

nozzle, as dripping may occur.

5.3

Start Spraying

5.3.1 turn the remote switch to on (I).

5.3.2 turn the broadcast lance valve on (fig.6).

5.3.3 to ensure a uniform spray pattern, overlap each spray

300mm (fig.7).

5.3.4 see the speed/application tables to determine the speed for

the AtV.

sYMPtoMs

rEAson

rEMEDY

Pump will not

start.

1. Poor electrical

connection.

2. short in wires

3. Low voltage.

1. Ensure good connections.

2. check conditions of wires.

3. check the battery voltage.

Low pressure. 1. Worn spray gun

nozzle.

2. Worn boom

nozzle.

1. replace spray gun nozzle.

2. replace boom nozzle.

Low flow.

1. clogged intake

tube.

2. clogged suction

strainer.

3. Low voltage.

1. remove obstruction to

intake tube.

2. clean suction strainer.

3. check the battery voltage.

Poor spray

distribution.

1. clogged intake

tube.

2. clogged suction

strainer.

3. Worn spray gun

nozzle

1. remove obstruction to

intake tube.

2. clean suction strainer.

3. replace spray gun nozzle.

Pump

operates while

not spraying.

1. Leak in the

system

1. Find leak and tighten hose

clamps or fittings.

replace spray gun.

6. TROUBLESHOOTING

Follow the below tables to determine the correct speed that the AtV

should travel.
7.1

Table 1

7.1.1 use the table that corresponds with the agents

manufacturer’s suggested application rate (litres per hectare,

litres per 100 sq.m or litres per 10 sq.m).

7.1.2 Find the application rate that is closest to the agents

manufacturer’s recommendations.

Litres per Hectare
Application rate

800

400

267

200

160

133

144

speed (km/h)

1

2

3

4

5

6

7

Litres per 100Sq.m.
Application rate

8.0

4.0

2.6

2.0

1.6

1.3

1.1

speed (km/h)

1

2

3

4

5

6

7

Litres per 10Sq.m.
Application rate

0.80 0.40 0.26 0.20 0.16 0.13 0.11

speed (km/h)

1

2

3

4

5

6

7

speed (km/h)

time required in seconds to travel a Distance of:

10m

50m

100m

1

36

180

360

2

18

90

180

3

12

60

120

4

9

45

90

5

7

35

70

6

6

30

60

7

5

25

50

7. SPRAY CALIBRATION

7.2

Table 2

7.2.1 use this table to set the speed of the AtV.

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: no liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK distributor, Sealey Group,

Kempson Way, suffolk business Park

,

bury st. Edmunds, suffolk,

IP32 7Ar

www.sealey.co.uk

Web

email

Original Language Version

ssA2 Issue:2(P)- 18/07/13

fig.5

fig.6

fig.7

NOTE! Refer to the manual for SS37 for maintenance and storage

instructions.