beautypg.com

England's Stove Works 60-SHBVNG User Manual

Page 9

background image

LIGHTING INSTRUCTIONS

1. STOP! Read “For Your Safety” above.

2. Set the thermostat to lowest setting.

3. Turn off all electric power to the appliance.

4. This appliance is equipped with a manual

piezoelectric ignition device. Do not attempt
to light the pilot by hand.


5. Turn gas valve control knob fully clockwise

to “OFF.”













6. Wait five (5) minutes to clear out any gas. If

you then smell gas, STOP! Follow the
“For Your Safety Read Before Lighting”
information earlier. If you do not smell gas,
go to the next step.


7. Be sure the thermostat is set at the lowest

setting.


8. Turn the gas valve control knob

counterclockwise

to “PILOT.”

9. Push in the gas valve control knob and hold

it in while pushing the button of the
piezoignitor. Push the piezoignitor button
several times while holding the gas valve
control knob in.


10. After the pilot has ignited, you may cease

pushing the piezoignitor button. Continue to
hold the gas valve control knob for
approximately 30-60 seconds. Release the
gas valve control knob and it will “pop” out.

If the knob does not pop up when

released, stop and immediately call your
service technician or gas supplier.

The pilot is now lit.


11. For the very first lighting, it may take several

attempts to purge air from the gas line. If
pilot ignition does not occur or the pilot goes
out, repeat steps 9 and 10.


12. Turn the gas valve control knob fully

counterclockwise

← to “ON.”


13. Turn on all power to appliance.

14. Set thermostat to desired setting.

15. If the appliance will not operate, follow the

instructions “TO TURN OFF GAS TO
APPLIANCE” and call your service
technician or gas supplier.


16. Shut the gas valve access door.

TO TURN OFF GAS TO APPLIANCE

1. Set the thermostat to lowest setting.

2. Turn off all electric power to the appliance if

service is to be performed.

3. Turn gas valve control knob fully clockwise

→ to “OFF.” Do not force.


4. Shut gas valve access door.









1. White Rogers Pilot Light Assembly

(located in the firebox)

2. Spill Switch (located in the draft hood

beneath the flue collar)

3. Wall

Thermostat

4. Piezoelectric

Spark

Ignitor (located near

the gas control valve)

This manual is related to the following products: